12CONTROL SUB FUNCTIONS

[6]Precautions during control

MELSEC-Q

(1)When step operation is carried out using interpolation control positioning data, the step function settings are carried out for the reference axis.

(2)When the step valid flag is ON, the step operation will start from the

beginning if the positioning start signal is turned ON while " Md.26 Axis operation status" is "step standing by". (The step operation will be carried out from the positioning data set in " Cd.3 Positioning start No.".)

[7] Step function settings

To use the "step function", write the data shown in the following table to the QD75 using the sequence program. Refer to section [4] "Using the step operation" for the timing of the settings.

The set details are validated when written to the QD75.

 

 

 

 

Setting

 

Buffer memory address

 

 

Setting item

Setting details

Axis

Axis

Axis

Axis

 

 

value

 

 

 

 

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set "0: Deceleration unit step" or "1: Data No.

 

 

 

 

 

Cd.34

 

Step mode

 

1544

1644

1744

1844

 

 

 

unit step".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cd.35

 

Step valid flag

1

Set "1: Carry out step operation".

1545

1645

1745

1845

 

 

 

 

 

 

 

 

 

 

 

 

 

Step start

 

Set "1: Step continue", depending on the stop

 

 

 

 

 

Cd.36

 

1546

1646

1746

1846

 

 

 

information

 

status.

 

 

 

 

 

 

 

 

 

 

 

Refer to Section 5.7 "List of control data" for details on the setting details.

12 - 62