12 CONTROL SUB FUNCTIONS

MELSEC-Q

(3)Add the following sequence program to the control program, and write it to the PLC CPU.

Example

External command valid signal

Write 1000000 to D108 and D109.

DTOP H0

K1514

D108

K1

TOP

H0

K62

K1

K1

TOP

H0

K1505

K1

K1

[Speed change processing] <Write the new speed. >

<Set the external command function selection to external speed change

request. >

<Set the external command signal input to valid.>

Input the external command signal.

(QD75 starts speed change processing.)