6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL

MELSEC-Q

Device

 

Device

 

Application

Details when ON

name

Axis 1

Axis 2

Axis 3

Axis 4

 

 

 

 

 

 

 

 

 

 

M0

 

 

 

OPR request OFF command

Commanding OPR request OFF

 

 

 

 

 

 

 

 

M1

 

 

 

OPR request OFF command pulse

OPR request OFF commanded

 

M2

 

 

 

OPR request OFF command storage

OPR request OFF command held

 

M3

 

 

 

Fast OPR command

Commanding fast OPR

 

M4

 

 

 

Fast OPR command storage

Fast OPR command held

 

 

 

 

 

 

 

 

M5

 

 

 

Positioning start command pulse

Positioning start commanded

 

 

 

 

 

 

 

 

M6

 

 

 

Positioning start command storage

Positioning start command held

 

M7

 

 

 

In-JOG/Inching operation flag

In-JOG/Inching operation flag

 

M8

 

 

 

Manual pulse generator operation

Commanding manual pulse generator

 

 

 

 

enable command

operation enable

 

 

 

 

 

 

 

 

 

 

 

 

 

M9

 

 

 

Manual pulse generator operating flag

Manual pulse generator operating flag

 

 

 

 

 

 

 

 

M10

 

 

 

Manual pulse generator operation

Commanding manual pulse generator

 

 

 

 

disable command

operation disable

 

 

 

 

 

 

M11

 

 

Speed change command pulse

Speed change commanded

 

M12

 

 

Speed change command storage

Speed change command held

 

 

 

 

 

 

 

 

 

 

 

 

M13

 

 

 

Override command

Requesting override

 

 

 

 

 

 

 

 

M14

 

 

 

Acceleration/deceleration time change

Requesting acceleration/deceleration

 

 

 

 

command

time change

 

 

 

 

 

 

M15

 

 

 

Torque change command

Requesting torque change

 

 

 

 

 

 

 

 

M16

 

 

 

Step operation command pulse

Step operation commanded

 

 

 

 

 

 

 

Internal relay

M17

 

 

 

Skip command pulse

Skip commanded

 

 

 

 

 

 

M18

 

 

 

Skip command storage

Skip command held

 

M19

 

 

 

Teaching command pulse

Teaching commanded

 

M20

 

 

 

Teaching command storage

Teaching command held

 

M21

 

 

 

Continuous operation interrupt

Requesting continuous operation

 

 

 

 

command

interrupt

 

 

 

 

 

 

 

 

 

 

 

 

 

M22

 

 

 

Restart command

Requesting restart

 

M23

 

 

 

Restart command storage

Restart command held

 

 

M24

 

Parameter initialization command

Parameter initialization commanded

 

 

 

pulse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M25

 

Parameter initialization command

Parameter initialization command held

 

 

 

storage

 

 

 

 

 

 

 

 

M26

 

Flash ROM write command pulse

Flash ROM write commanded

 

 

M27

 

Flash ROM write command storage

Flash ROM write command held

 

M28

 

 

 

Error reset

Error reset completed

 

 

 

 

 

 

 

 

M29

 

 

 

Stop command pulse

Stop commanded

 

 

 

 

 

 

 

 

M30

 

 

 

Target position change command

Target position change commanded

 

 

 

 

pulse

 

 

 

 

 

 

 

M31

 

 

Target position change command

Target position change command held

 

 

 

 

storage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M32

 

 

 

PSTRT1 instruction complete device

PSTRT1 instruction completed

 

 

 

 

 

 

 

 

M33

 

 

 

PSTRT1 instruction error complete

PSTRT1 instruction error completed

 

 

 

 

device

 

 

 

 

 

 

6 - 7