9 MAJOR POSITIONING CONTROL

9.1.2 Operation patterns of major positioning controls

MELSEC-Q

In "major positioning control" (high-level positioning control), " Da.1 Operation pattern" can be set to designate whether to continue executing positioning data after the started positioning data. The "operation pattern" includes the following 3 types.

Positioning complete

(1) Independent positioning control

 

(operation pattern: 00)

Positioning continue

(2) Continuous positioning control

 

(operation pattern: 01)

(3)Continuous path control (operation pattern: 11)

The following shows examples of operation patterns when "1-axis linear control (ABS linear 1)" is set in positioning data No. 1 to No. 6 of axis 1. Details of each operation pattern are shown on the following pages.

< Operation example when "1-axis linear positioning" is set in the positioning data of axis 1 >

(Setting details)

 

 

 

No.1 Start

 

Positioning data No.1 Positioning to address [A] at command speed [a]

 

 

 

 

 

Operation pattern = 11: Continuous path control

 

 

 

No.2

 

Operation pattern = 11: Continuous path control

 

 

 

Positioning to address [B] at command speed [b]

 

 

 

No.3

 

Operation pattern = 01: Continuous positioning control

 

 

 

Positioning to address [C] at command speed [a]

 

 

 

No.4

 

Operation pattern = 01: Continuous positioning control

 

 

 

Positioning to address [D] at command speed [b]

 

 

 

 

 

 

 

 

 

 

No.5

 

Operation pattern = 00: Independent positioning control

 

Positioning to address [E] at command speed [a]

 

 

 

(Positioning complete)

 

 

No.6

 

Control stop

 

Positioning to address [F] at command speed [a]

 

 

 

 

 

Operation pattern = 11: Continuous path control

 

Speed

 

Operation pattern

 

 

 

b

 

 

11

 

11

01

 

a

 

 

 

Speed is changed

 

 

 

 

 

 

 

 

without stopping

01

00

The machine stops, and then continues the next positioning.

Positioning is terminated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

 

 

No.2

 

 

No.3

 

 

No.4

 

 

No.5

 

 

 

 

 

0

 

 

NO.1

 

 

 

 

 

 

 

 

 

 

 

 

Address

 

 

 

 

D

 

 

 

 

(Positioning data)A

 

B

C

E

F

 

 

 

 

 

 

 

(Direction in which axis 1 addresses increase)

For 1-axis linear control

(One motor is driven, and positioning is carried out to an addresses designated in one direction.)

POINT

The BUSY signal [XC, XD, XE, XF] turns ON even when position control of movement amount 0 is executed. However, since the ON time is short, the ON status may not be detected in the sequence program.

9 - 5

Page 305