13 COMMON FUNCTIONS

13.5 External I/O signal monitor function

MELSEC-Q

The "External I/O signal monitor function" monitors the module's information and external I/O signal monitor information in the module's detailed information which can be displayed on the system monitor of GX Developer .

The information that can be monitored are the module's information (same as the QD75 front "RUN", "ERR" LED indicators) and the following external I/O signals. (Set the logic of the external I/O signals in " Pr.22 Input signal logic selection"

and " Pr.23 Output signal logic selection".)

0:OFF, 1:ON

Axis-by-axis external I/O signals and module RUN, ERR LEDs

Indicates that Drive unit ready of axis 1 is ON.

: Use GX Developer of "SW6D5C-GPPW-E or later". Refer to GX Developer Operating Manual for the system monitor of GX Developer.

13 - 8

Page 582
Image 582
Mitsubishi Electronics QD75P, QD75D user manual External I/O signal monitor function