15 TROUBLESHOOTING

MELSEC-Q

Classification

Error

Error name

Error

Operation status at error occurrence

 

of errors

code

 

 

 

 

 

 

 

 

 

 

 

 

900

Outside unit setting

The set range of the basic parameter

 

 

 

range

1 "Unit setting" is outside the setting

 

 

 

 

 

range.

 

 

 

 

Outside pulse

The set range of the basic parameter

 

 

 

901

number per rotation

1 "No. of pulses per rotation" is

 

 

 

 

range

outside the setting range.

 

 

 

 

Outside movement

The set range of the basic parameter

 

 

 

902

amount per rotation

1 "Movement amount per rotation" is

 

 

 

 

range

outside the setting range.

 

 

 

 

 

 

 

 

 

 

Outside unit

The set range of the basic parameter

 

 

 

903

1 "Unit magnification" is outside the

 

 

 

magnification range

The QD75 READY signal (X0) is not

 

 

 

 

setting range.

turned ON.

 

 

 

Pulse output mode

The set range of the basic parameter

 

 

904

1 "Pulse output mode" is outside the

 

 

 

 

error

setting range.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rotation direction

The set range of the basic parameter

 

 

 

905

1 "Rotation direction setting" is

 

 

 

setting error

 

 

 

 

 

outside the setting range.

 

 

 

 

 

• The set range of the basic

 

 

 

 

Outside bias speed

parameter 1 "Bias speed at start" is

 

 

 

906

outside the setting range.

 

 

 

range

 

 

 

• The bias speed exceeds the speed

 

 

 

 

 

 

 

 

 

 

limit.

 

 

 

 

 

• The set range of the basic

 

 

Parameter

 

 

parameter 2 "Speed limit value" is

 

 

 

 

outside the setting range.

 

 

 

 

 

 

 

 

 

 

• The value obtained by the

 

 

 

910

Outside speed limit

conversion of the speed limit value

 

 

 

value range

with respect to the frequency

When the power is turned ON or PLC

 

 

 

 

exceeds the maximum output

READY signal (Y0) is turned from

 

 

 

 

frequency of the unit.

OFF to ON:

 

 

 

 

• The speed limit value is smaller

QD75 READY signal (X0) is

 

 

 

 

than the OPR speed.

not turned ON.

 

 

911

Outside acceleration

The set range of the basic parameter

At start: The system will not operate.

 

 

time 0 range

2 "Acceleration time 0" is outside the

 

 

 

 

setting range.

 

 

 

 

 

 

 

 

 

Outside deceleration

The set range of the basic parameter

 

 

 

912

2 "Deceleration time 0" is outside the

 

 

 

 

time 0 range

setting range.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Backlash

The value converted into pulse

 

 

 

920

compensation

number using the movement amount

 

 

 

 

amount error

per pulse is 256 pulses or more.

 

 

 

 

 

• In the unit of degree, the set value

 

 

 

 

 

of the detailed parameter 1

The QD75 READY signal (X0) is not

 

 

 

 

"Software stroke limit upper limit

 

 

 

 

turned ON.

 

 

921

Software stroke limit

value" is outside the setting range.

 

 

 

 

 

 

 

upper limit

• In a unit other than degree, the

 

 

 

 

 

software stroke limit upper limit

 

 

 

 

 

value is smaller than the software

 

 

 

 

 

stroke limit lower limit value.

 

 

 

 

 

 

 

 

15 - 24

Page 628