5 - 76
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
REMARK
To perform an high-level positioning control using block start data, set a numberbetween 7000 and 7004 to the " Cd.3 Positioning start No." and use the"Cd.4 Positioning starting point No." to specify a point number betw een 1 an d 50 , aposition counted from the beginning of the bl ock.The number between 7000 and 7004 specified here is called the "block No.".With the QD75, up to 50 "block start data" p oints and up to 10 "condition data" item scan be assigned to each "block No.".
Block
No. Axis Block start data Condition Buffer memory GX
Configurator-
QP
Axis 1 Condition data (1 to 10)
Axis 2 Condition data (1 to 10)
Axis 3 Condition data (1 to 10)
7000
Axis 4
Start block 0
Condition data (1 to 10)
Axis 1 Condition data (1 to 10)
Axis 2 Condition data (1 to 10)
Axis 3 Condition data (1 to 10)
7001
Axis 4
Start block 1
Condition data (1 to 10)
Axis 1 Condition data (1 to 10)
Axis 2 Condition data (1 to 10)
Axis 3 Condition data (1 to 10)
7002
Axis 4
Start block 2
Condition data (1 to 10)
Axis 1 Condition data (1 to 10)
Axis 2 Condition data (1 to 10)
Axis 3 Condition data (1 to 10)
7003
Axis 4
Start block 3
Condition data (1 to 10)
Axis 1 Condition data (1 to 10)
Axis 2 Condition data (1 to 10)
Axis 3 Condition data (1 to 10)
7004
Axis 4
Start block 4
Condition data (1 to 10)
Supports the
settings Supports the
settings
: Setting cannot be made when the "Pre-reading start function" is used. If you set any of Nos.
7000 to 7004 and perform the Pre-reading start function, "Outside start No. range error
(error code: 543)" will occur.
(For details, refer to Section 12.7.8 "Pre-reading start function".)