14 - 7
MELSEC-Q
14 DEDICATED INSTRUCTIONS
(6) If the ABRST instruction is exec uted in either of the following cases, an error
"Dedicated instruction error" (error code: 804) will occur and absolute position
restoration cannot be carried out.
• Any value other than 0 is set to "Status" (de vice: (S)+4) of the control data.
• The instruction for a non-existent axis is specified.
(Example: The ABRST2 instruction is spec ified when the QD75P1 is used.)
[Program examples]
Program to restore the absolute position of axis 1.
The X47 to X49 and Y50 to Y52 are used for communication with the se rvo
amplifier.
X47: ABS data bit 0
X48: ABS data bit 1
X49: T ransmission data READY flag
Y50: Ser vo ON signal
Y51: ABS transfer mode
Y52: ABS request flag
No. 23 Absolute position restoration program
(1) Absolute position restoration command acceptance
(2) Setting of transmit data to servo-amplifier and confirmation of absolute position restoration completion
ABRST1 instruction completed when M42 is ON and M43 is OFF.
Absolute position data restoration completed when status = 0.
(3) ABS data setting and ABRST1 instruction execution
<Status reset>
<Error code transmission to D49>
<ABS data bit 0 ON/OF>
<ABS data bit 1 ON/OF>
<Transmission data preparation
complete flag ON/OFF>
<ABRST1 instruction execution>