DSL-604+ ADSL Ethernet Router User’s Guide

 

Figure 4- 30. Line Condition

 

 

 

 

 

Disconnected - ADSL connection failure

 

ADSL State

Idle - valid connection currently not active

Protocol

 

Active - valid connection that currently transmitting packets

 

 

Data Path

Current data path type Fast or Interleaved

 

 

 

 

 

Operation Mode

Modulation technique used for ADSL connection,

 

G.DMT or G.lite

 

 

 

 

 

 

ADSL Link Speed

Downstream/Upstream data transfer rate in Kbps

 

 

 

Link Status

SNR

Downstream/Upstream Signal-to-Noise Ratio in dB

 

 

 

 

ATTEN

Downstream/Upstream attenuation of signal in dB

 

 

 

 

FEC

FEC Forward Error Correction

 

 

 

Line Error

CRC

CRC Cyclic Redundancy Control

 

 

 

 

HEC

HEC Header Error Check

 

 

 

Frame Counter

Number of data packets received and transmitted

 

 

 

Loop Distance

 

Loop in K ft. (range = 0 – 18 K ft.)

 

 

 

Use the Clear button to start a fresh session. Check the Auto-Refreshbox to automatically refresh the screen.

Carrier Chart

51

Page 61
Image 61
D-Link DSL-604+ manual Carrier Chart