Mitsubishi Electronics QD75P, QD75D user manual Pr.48 OPR retry

Models: QD75P QD75D

1 768
Download 768 pages 34.72 Kb
Page 140
Image 140

5DATA USED FOR POSITIONING CONTROL

Pr.48 OPR retry

MELSEC-Q

Set whether to carry out OPR retry.

When the OPR retry function is validated and the machine OPR is started, first the axis will move in the OPR direction (1)). If the upper/lower limit signal turns OFF before the near-point dog signal ON is detected (2)), the axis will decelerate to a stop, and then will move in the direction opposite to the specified OPR direction (3)). If the falling edge of the near-point dog signal is detected during movement in the opposite direction, the axis will decelerate to a stop (4)), and will carry out machine OPR again (5), 6)).

5)

1)

2)

 

6)

Start position

4)

3)

ON

Limit signal OFF state

Near-point dog signal

Zero signal

[Operation for OPR retry function]

1)Movement in the OPR direction starts with the machine OPR start.

2)The axis decelerates when the limit signal OFF is detected.

3)After stopping at detection of the limit switch signal OFF, the axis moves at the OPR speed in the direction opposite to the specified OPR direction.

4)The axis decelerates when the near-point dog signal turns OFF.

5), 6) After stopping with the near-point dog signal OFF, carries out machine OPR in the OPR direction.