8 OPR CONTROL

MELSEC-Q

(3)If the zero signal is input before the workpiece stops at the stopper, the workpiece will stop at that position, and that position will be regarded as the OP.

 

 

 

V

Pr. 46 OPR speed

 

 

 

 

 

 

 

 

 

 

 

Pr. 47 Creep speed

 

 

 

 

 

Stops at stopper

 

 

 

 

 

t

 

 

 

 

Zero signal

 

 

 

 

 

Valid torque limit range

 

 

 

 

Torque limit

 

 

 

 

 

ON

 

 

 

 

 

Near-point dog OFF

 

 

 

 

 

ON

 

Machine OPR start

OFF

 

 

 

 

 

 

 

(Positioning start signal)

 

 

 

 

 

 

 

 

ON

 

OPR request flag

OFF

 

 

 

 

 

 

 

[

Status : b3]

 

 

 

 

 

 

 

 

 

ON

OPR complete flag

OFF

 

 

 

[ Md.31 Status : b4]

 

 

 

 

Deviation counter clear output

 

 

Pr.55 Deviation counter clear signal

 

 

 

 

 

 

 

 

 

 

output time

 

Axis operation status

Standing by

 

In OPR

Standing by

Md.34 Movement amount

Inconsistent

 

0

 

after near-point dog ON

 

 

 

 

 

Current feed value

Inconsistent

 

Value the machine moved is stored

OP address

 

 

 

Machine feed value

Fig. 8.9 Operation when the zero signal is input before the stop at the stopper

(4) Machine OPR started while the near-point dog is ON will start at the "

Pr.47

Creep

speed".

(5)When a machine OPR is stopped with the stop signal, perform a machine OPR again. If the restart command is turned ON after a stop with the stop signal, an error "OPR restart not possible" (error code: 209) occurs.

8 - 13

Page 291
Image 291