7 - 3
MELSEC-Q
7 MEMORY CONFIGURATION AND DATA PROCESS
Details of areas
Parameter area
Area where parameters, such as positioning par ameters and OPR parameters,
required for positioning control are set and s tored.
(Set the items indicated with Pr.1 to Pr.57 , Pr.150 for each axis.)
Monitor data area
Area where positioning system or QD75 opera tion state is stored.
(Set the items indicated with Md.1 to
Md.48
.)
Control data area
Area where data for operating and controlling positioning system is set and
stored. (Set the items indicated with Cd.1 to
Cd.42
.)
Positioning data area (No.1 to 600)
Area where positioning data No.1 to 600 is s et and stored.
(Set the items indicated with Da.1 to Da.10 for each positioning data.)
Block start data area (No.7000 to 7004)
Area where information required only when carrying out block No. 7000 to 7004
high-level positioning is set and stored. (Se t the items indicated with Da.11 to
Da.19 .)
PLC CPU memo area
Area where condition judgment values requir ed for special positioning, etc., are
set and stored.