5 - 84

MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Da.15 Condition target

Set the condition target as required for each control.

Setting value Setting details
01H : Device X
02H : Device Y Set the input/output signal ON/OFF as the conditions.
03H : Buffer memory (1-word)
04H : Buffer memory (2-word)
Set the value stored in the buffer memory as the condition.
03H: The target buffer memory is "1-word (16 bits)"
04H: The target buffer memory is "2-word (32 bits)"
05H : Positioning data No. Select only for "simultaneous start".
Da.16 Condition operator

Set the condition operator as required for the " Da.15 Condition target".

Da.15 Condition target Setting value Setting details
07H :DEV=ON
01H: Device X
02H: Device Y 08H :DEV=OFF The state (ON/OFF) of an I/O signal is defined as the
condition. Select ON or OFF as the trigger.
01H :
=P1
02H :
P1
03H :
P1
04H :
P1
05H :P1
P2
03H: Buffer memory (1-word)
04H: Buffer memory (2-word)
06H :
P1, P2
Select how to use the value (
) in the buffer memory
as a part of the condition.
10H :Axis 1 selected
20H :Axis 2 selected
30H :Axes 1 and 2 selected
40H :Axis 3 selected
50H :Axes 1 and 3 selected
60H :Axes 2 and 3 selected
70H :Axes 1, 2, and 3 selected
80H :Axis 4 selected
90H :Axes 1 and 4 selected
A0H :Axes 2 and 4 selected
B0H : Axes 1, 2, and 4 selected
C0H :Axes 3 and 4 selected
D0H :Axes 1, 3, and 4 selected
05H: Positioning data No.
E0H :Axes 2, 3, and 4 selected
If "simultaneous start" is specified, select the axis
(or axes) that should start simultaneously.
Da.17 Address

Set the address as required for the " Da.15 Condition target".

Da.15 Condition target Setting value Setting details
01H : Device X
02H : Device Y Not used. (There is no need to set.)
03H : Buffer memory (1-word)
04H : Buffer memory (2-word) Value
(Buffer memory address)
Set the target "buffer memory address".
(For 2 word, set the low-order buffer memory
address.)
05H : Positioning data No. Not used. (There is no need to set.)