8 OPR CONTROL

MELSEC-Q

OPR sub functions

Refer to Section 3.2.4 "Combination of QD75 main functions and sub functions" for details on "sub functions" that can be combined with OPR control. Also refer to Chapter 12 "Control sub functions" for details on each sub function.

[Remarks]

The following two sub functions are only related to machine OPR.

Sub function name

 

 

Machine OPR

Fast OPR

Reference

OPR retry function

 

 

 

 

 

 

Section 12.2.1

 

 

 

 

 

 

 

 

OP shift function

 

 

 

 

 

 

Section 12.2.2

 

 

 

 

 

 

: Combination possible,

 

: Restricted, : Combination not possible

 

When an OPR is not required

Control can be carried out ignoring the "OPR request flag" ( Md.31 Status: b3) in systems that do not require an OPR.

In this case, the "OPR parameters ( Pr.43 to Pr.57 )" must all be set to their initial values or a value at which an error does not occur.

OPR from peripheral devices

"Machine OPR" and "fast OPR" can be executed from the test mode of the peripheral device.

Refer to GX Configurator-QP Operating Manual for details on OPR from the peripheral device.

8 - 3

Page 281
Image 281
Mitsubishi Electronics QD75D, QD75P user manual OPR sub functions, When an OPR is not required, OPR from peripheral devices