APPENDICES

MELSEC-Q

 

Model

QD75P1

 

QD75P2

QD75P4

A1SD75P1

 

A1SD75P2

 

A1SD75P3

Item

 

QD75D1

 

QD75D2

QD75D4

-S3

 

-S3

 

-S3

 

STRT signal

 

(integrated into "CHG")

 

(External start signal)

 

 

External command signal (External start or

 

 

 

 

 

I/O signal for

CHG signal

speed-position switching selectable with

Speed-position switching signal

external devices

 

parameters)

 

 

 

 

 

 

 

In-position (INP)

 

 

 

 

 

 

(for monitor)

 

 

 

 

 

 

 

 

 

Signal logic switching

 

 

 

 

Command pulse output signal only

 

 

 

 

 

 

 

 

 

 

 

Connection via PLC CPU,

 

 

 

 

 

 

 

Connection with peripheral

Q Corresponding Serial Communication

 

Direct connection

 

 

devices

Module, Q Corresponding MELSEC/H

 

 

 

 

 

 

 

 

Peripheral devices

 

Remote I/O Module

 

 

 

 

 

 

AD71TU

 

 

 

 

 

 

 

 

 

(data setting, etc.)

 

 

 

 

 

 

 

 

 

 

AD75TU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A6GPP, A6PHP

DOS/V personal computer

: Possible, : Not possible

1: Up to 100 data items/axis of positioning data (No. 1 to 100) can be set using the buffer memory. The positioning data in the buffer memory is not backed up.

2: Indicates the standard mode/stepping motor mode about A1SD75P-S3.

3: Indicates the INC mode/ABS mode in speed-position switching control.

4: The deviation counter clear signal output time can be set with parameters.

5: The near pass function is valid only during the continuous path control. (A1SD75: Selected with parameters, QD75: Standard function)

(2) Function comparisons

Functions added to those of A1SD75P1-S3/A1SD75P2-S3/A1SD75P3-S3

 

Added functions

Remarks

External I/O signal logic switching function

Refer to Section 13.4.

Inching operation

 

Refer to Section 11.3.

Target position change function

Refer to Section 12.7.5.

Multiple axes simultaneous start control

Refer to Section 10.5.

 

3-axis linear interpolation control

 

 

4-axis linear interpolation control

 

 

3-axis fixed-feed control

 

 

4-axis fixed-feed control

 

Control systems

2-axis speed control

Refer to Chapter 9.

3-axis speed control

 

 

 

4-axis speed control

 

 

Position-speed switching control

 

 

NOP instruction

 

 

LOOP instruction, LEND instruction

 

 

Absolute position restoration

 

Dedicated

Positioning start

 

Teaching

Refer to Chapter 14.

instructions

Flash ROM writing

 

 

 

 

Parameter initialization

 

Automatic refresh of intelligent function modules

Refer to GX Configurator-QP Operating Manual.

Output hold/clear parameter setting during PLC CPU error stop

Refer to QCPU User's Manual

(Function Explanation, Program Fundamentals).

 

 

Flash ROM write limit

 

Refer to Section 13.3.

Speed-position switching control (ABS mode)

Refer to Section 9.2.7.

Pre-reading start function

Refer to Section 12.7.8.

External I/O signal monitor function

Refer to Section 13.5.

Multiple PLC compatible function

Refer to QCPU User's Manual (Multiple CPU System).

Deceleration start flag function

Refer to Section 12.7.9

Stop command processing for deceleration stop function

Refer to Section 12.7.10

Appendix - 47

Page 689
Image 689
Mitsubishi Electronics QD75D, QD75P user manual Function comparisons