11 - 9
MELSEC-Q
11 MANUAL CONTROL
Setting item Setting requirement Factory-set initial value
(setting details)
Pr.25 Acceleration time 1 (Unit: pulse) 1000
Pr.26 Acceleration time 2 (Unit: pulse) 1000
Pr.27 Acceleration time 3 (Unit: pulse) 1000
Pr.28 Deceleration time 1 (Unit: pulse) 1000
Pr.29 Deceleration time 2 (Unit: pulse) 1000
Pr.30 Deceleration time 3 (Unit: pulse) 1000
Pr.31 JOG speed limit value (Unit: pulse/s) 20000
Pr.32 JOG operation acceleration time selection 0 (acceleration time 0)
Pr.33 JOG operation deceleration time selection 0 (deceleration time 0)
Pr.34 Acceleration/deceleration process selection 0 (trapezoidal acceleration/
deceleration processing)
Pr.35 S-pattern proportion (Unit: %) 100
Pr.36 Sudden stop deceleration time (Unit: ms) 1000
Pr.37 Stop group 1 sudden stop selection 0 (deceleration stop)
Pr.38 Stop group 2 sudden stop selection 0 (deceleration stop)
Parameters
Pr.39 Stop group 3 sudden stop selection 0 (deceleration stop)
: Setting always required.: Set according to requirements (Leave set t o the initial value when not used.)