11 MANUAL CONTROL

11.2.3 Setting the required parameters for JOG operation

MELSEC-Q

The "Parameters" must be set to carry out JOG operation.

The following table shows the setting items of the required parameters for carrying out JOG operation. When only JOG operation will be carried out, no parameters other than those shown below need to be set. (Use the initial values or setting values within a range where no error occurs for trouble-free operation.)

Parameters

 

 

 

 

Setting item

Setting requirement

Factory-set initial value

 

 

 

 

(setting details)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.1

 

 

Unit setting

 

 

 

3 (pulse)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.2

 

 

No. of pulses per rotation (Ap) (Unit: pulse)

 

 

 

20000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.3

 

 

Movement amount per rotation (Al) (Unit: pulse)

 

 

 

20000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.4

 

 

Unit magnification (Am)

 

 

 

1 (1-fold)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.5

 

 

Pulse output mode

 

 

 

1 (CW/CCW mode)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 (current value increases by

 

Pr.6

 

 

Rotation direction setting

 

 

 

forward run pulse output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.7

 

Bias speed at start (Unit: pulse/s)

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.8

 

 

Speed limit value (Unit: pulse/s)

 

 

 

20000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.9

 

 

Acceleration time 0 (Unit: pulse/s)

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.10

 

Deceleration time 0 (Unit: pulse/s)

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.11

 

Backlash compensation amount (Unit: pulse)

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.12

 

Software stroke limit upper limit value (Unit: pulse)

 

 

 

2147483647

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.13

 

Software stroke limit lower limit value (Unit: pulse)

 

 

 

–2147483648

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.14

 

Software stroke limit selection

 

 

 

0 (current feed value)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.15

 

Software stroke limit valid/invalid setting

 

 

 

0 (valid)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.17

 

Torque limit setting value (Unit: %)

 

 

 

300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 (Pulse output to drive unit is

 

Pr.23

 

Output signal logic selection

 

 

 

 

 

 

 

 

negative logic.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

:Setting always required.

:Set according to requirements (Leave set to the initial value when not used.)

REMARK

Parameter settings work in common for all control using the QD75. When carrying out other control ("major positioning control", "high-level positioning control", "OPR positioning control"), the respective setting items must also be matched and set.

Parameters are set for each axis.

Refer to Chapter 5 "Data Used for Positioning Control" for setting details.

11 - 8