2 SYSTEM CONFIGURATION

2.3 Applicable system

The QD75 can be used in the following system.

MELSEC-Q

(1) Applicable modules and the number of installable modules

The following table indicates the CPU modules and network modules (for remote I/O station) usable with the QD75 and the number of installable modules.

Applicable modules

Number of installable modules

Remarks

 

Q00JCPU

Max. 16 modules

 

 

 

Q00CPU

Max. 24 modules

(

1)

 

Q01CPU

 

 

 

 

 

 

 

Q02CPU

 

 

 

CPU

Q02HCPU

 

Installable in the Q mode

module

Q06HCPU

Max. 64 modules

only

 

Q12HCPU

 

(

1)

 

Q25HCPU

 

 

 

 

Q12PHCPU

Max. 64 modules

(

1)

 

Q25PHCPU

 

 

 

 

 

QJ72LP25-25

 

 

 

Network

QJ72BR15

Max. 64 modules

MELSECNET/H remote I/O

module

QJ72LP25G

station ( 2)

 

 

QJ72LP25GE

 

 

 

1 Refer to the User's Manual (Hardware Design, Maintenanse and Inspection) of the CPU module used.

2 Refer to the Q Corresponding MELSECNET/H Network System Reference Manual (Remote I/O Network).

(2) Usable base unit

The QD75 can be installed in any of the I/O slots ( 3) of a base unit.

When installing the QD75, always consider the power supply capacity since a shortage of the power supply capacity may occur depending on the combination with the other installed module and the number of installed module.

3 Within the I/O point range of the CPU module and network module (for remote I/O station).

(3) Compatibility with multiple PLC system

When using the QD75 in a multiple PLC system, first refer to the QCPU (Q mode) User's Manual (Function Explanation, Program Fundamentals).

(4) Supported software packages

The following table lists the compatibility between the systems using the QD75 and the software packages. GX Developer is required for use of the QD75.

 

 

Software version

 

 

GX Developer

GX Configurator-QP

 

Single PLC

Version 7 or more

 

 

system

 

Q00J/Q00/Q01CPU

 

 

Multiple PLC

 

 

 

Version 8 or more

 

 

system

 

 

 

Version 2.10L or more

 

Single PLC

 

 

Version 4 or more

 

Q02/Q02H/Q06H/

system

 

 

 

Q12H/Q25HCPU

Multiple PLC

Version 6 or more

 

 

system

 

 

 

 

 

Single PLC

 

 

Q12PH/Q25PHCPU

system

Version 7.10L or more

Version 2.13P or more

Multiple PLC

 

 

 

 

system

 

 

For use on MELSECNET/H remote

Version 6 or more

Version 2.10L or more

I/O station

 

 

 

 

 

2 - 5

 

 

Page 47
Image 47
Mitsubishi Electronics QD75D Applicable system, Applicable modules and the number of installable modules, Usable base unit