5 DATA USED FOR POSITIONING CONTROL

MELSEC-Q

 

Item

 

 

 

 

Setting value

 

 

 

 

 

 

 

 

Default

Setting value buffer memory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

value

 

address

 

 

 

 

 

 

Value set with peripheral device

 

 

Value set with sequence program

Axis 1

Axis 2

Axis 3

Axis 4

 

Da.1

00:Positioning complete

00

 

 

 

 

Operation pattern

 

 

 

 

 

 

01:Continuous positioning control

01

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pattern

11:Continuous path control

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABS1

:1-axis linear control (ABS)

01H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INC1

 

:1-axis linear control (INC)

02H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEED1:1-axis fixed-feed control

03H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VF1

 

 

:1-axis speed control (forward run)

04H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VR1

 

 

:1-axis speed control (reverse run)

05H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VPF

 

 

:Speed-position switching control (forward

06H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

run)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VPR

 

 

:Speed-position switching control (reverse

07H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

run)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVF

 

 

: Position-speed switching control (forward

08H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

run)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PVR

 

 

:Position-speed switching control (reverse

09H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

run)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABS2

:2-axis linear interpolation control (ABS)

0AH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INC2

 

:2-axis linear interpolation control (INC)

0BH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEED2:Fixed-feed control by 2-axis linear

0CH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

interpolation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABS

 

(

:Circular interpolation control with sub point

0DH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specified (ABS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INC

(

:Circular interpolation control with sub point

0EH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specified (INC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABS . :Circular interpolation control with center

0FH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

point specified (ABS, CW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABS . :Circular interpolation control with center

10H

 

 

 

Control system

 

 

 

 

 

 

 

Da.2

 

 

 

 

point specified (ABS, CCW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control

INC .

 

:Circular interpolation control with center

11H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

system

 

 

 

 

point specified (INC, CW)

 

 

 

 

 

 

Setting value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INC .

 

:Circular interpolation control with center

 

 

 

 

 

 

 

 

 

 

 

 

identifier

 

 

12H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

point specified (INC, CCW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VF2

 

 

:2-axis speed control (forward run)

13H

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

VR2

 

 

:2-axis speed control (reverse run)

14H

 

 

 

 

 

 

 

 

 

 

 

 

 

Positioning

 

 

 

 

 

 

 

 

 

 

 

0000H

2000

8000

14000

20000

 

ABS3

:3-axis linear interpolation control (ABS)

15H

 

 

 

 

 

 

 

 

 

INC3

 

:3-axis linear interpolation control (INC)

16H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEED3:Fixed-feed control by 3-axis linear

17H

 

 

 

 

 

 

Convert into

 

 

 

 

 

 

 

 

 

 

 

 

interpolation control

 

 

 

 

 

 

 

hexadecimal

 

 

 

 

 

 

 

VF3

 

 

:3-axis speed control (forward run)

18H

 

b15

b12

b8

b4

b0

 

 

 

 

 

 

 

VR3

 

 

:3-axis speed control (reverse run)

19H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABS4

:4-axis linear interpolation control (ABS)

1AH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INC4

 

:4-axis linear interpolation control (INC)

1BH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEED4:Fixed-feed control by 4-axis linear

1CH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

interpolation control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VF4

 

 

:4-axis speed control (forward run)

1DH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VR4

 

 

:4-axis speed control (reverse run)

1EH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOP

 

:NOP instruction

80H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POS

 

 

:Current value changing

81H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JUMP

:JUMP instruction

82H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOOP :Declares the beginning of LOOP to LEND

83H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEND

:Declares the end of LOOP to LEND

84H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:

Pr.9 Acceleration time 0

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Da.3

1:

Pr.25 Acceleration time 1

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acceleration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

time No.

2:

 

 

 

Acceleration time 2

10

 

Acceleration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3:

Pr.27 Acceleration time 3

11

 

time

 

 

 

 

 

 

 

 

 

 

 

 

0:

Pr.10 Deceleration time 0

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Da.4

1:

Pr.28 Deceleration time 1

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Deceleration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

time No.

2:

 

 

 

Deceleration time 2

10

 

Deceleration time

 

 

 

 

 

 

 

 

3:

Pr.30 Deceleration time 3

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: Axis1

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Da.5

1: Axis 2

01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis to be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2: Axis 3

10

 

Axis to be interpolated

 

 

 

 

 

 

 

interpolated

 

 

 

 

 

 

 

 

 

3: Axis 4

11

 

(in 2-axis interpolation only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 - 60

Page 148
Image 148