LMAC Linear Induction Motor

General Description: Single or three phase, linear AC induction motor primary.

Construction:Epoxy encapsulated and steel laminated coil assembly (motor primary) Motor secondary (customer supplied) must conform to the following specifications: 1/8–inch aluminum or copper plate backed by a 1/4 inch cold rolled steel plate. The width of the secondary must be at least the with of the motor coil assembly.

Maintenance:Motor should be kept dry and relatively free of contamination. This motor is water resistant, not water proof. Avoid submersion. Avoid contact with petroleum–based solvents. Alcohol or soapy water can be used to remove contaminants.

Motor specifications: Refer to catalog or outline drawing supplied with motor for mechanical dimensions and electrical specifications.

Motor Mounting:Your motor may be supplied with either base or foot mounting, refer to catalog or outline drawing supplied with motor for mounting details and hole dimensions. It is recommended that all available coil assembly mounting holes be utilized to properly secure the coil assembly. If the coil is in motion, the motor wires must be strain relieved. We recommend that the motor secondary be secured with 1/4inch fasteners on the left and right sides of the secondary, every four to six inches of its length. An air–gap of 1/8 inch is recommended. Refer to linear induction motor duty cycle–force–current curves in this booklet for information regarding the affects of air–cap size on motor performance.

Electrical Connections For voltage and current specifications, refer to Catalog BR1800 or to documentation enclosed for custom motors. The 10 foot flying leads can be cut to remove excess length if required. Connectors are available; contact a Baldor representative for more information.

For single phase motors, refer to the table supplied with this booklet for capacitor selection.

Motor Wire

Function

Gauge

Color

Phase A

10

Red

Phase B

10

Blue (substituted by black in older models)

Phase C

10

White

Ground

 

Motor housing

Thermal switch

20

Orange (two wires, interchangeable)

Thermal warning

20

Black (two wires, interchangeable)

LMAC Connection Diagram

2-2 Installation & Operation

MN1800

Page 9
Image 9
Baldor iMN1800 manual Lmac Linear Induction Motor, Lmac Connection Diagram

iMN1800 specifications

The Baldor iMN1800 is a comprehensive industrial motor drive, engineered for a wide range of applications in various sectors such as manufacturing, robotics, and automation. This drive exemplifies Baldor's commitment to innovation, performance, and efficiency, offering users advanced features that cater to modern industrial demands.

At the heart of the iMN1800 is its state-of-the-art motor control technology, designed to provide precise control over motor speed and torque. This is achieved through a sophisticated algorithm that adjusts the motor's performance in real-time, ensuring reliability and efficiency. The iMN1800 is compatible with various forms of electric motors, including AC induction and permanent magnet synchronous motors, making it versatile for numerous applications.

One of the standout features of the Baldor iMN1800 is its energy efficiency. It complies with various energy standards, which not only helps reduce operational costs but also minimizes the environmental impact associated with industrial operations. With an impressive efficiency rating, the iMN1800 contributes to lower energy consumption, making it an economically viable solution for businesses aiming to enhance sustainability.

In terms of connectivity, the iMN1800 incorporates advanced communication protocols such as Ethernet/IP and Modbus, allowing for seamless integration into existing industrial networks. This feature facilitates real-time monitoring and control, empowering operators to make informed decisions based on live data. The user-friendly interface enables quick access to essential parameters for both configuration and diagnostics, ensuring ease of use for technicians and engineers alike.

Moreover, the iMN1800 is built with robust construction materials, ensuring durability in demanding environments. Its rugged design allows it to withstand harsh conditions, including high temperatures and vibrations, common in industrial settings. This reliability contributes to reduced downtime and maintenance costs, promoting a more productive work environment.

The Baldor iMN1800 also features advanced safety mechanisms, including overload protection and short-circuit protection, guaranteeing the safety of both personnel and equipment. These attributes align with modern safety standards, making it a trusted choice for industries that prioritize workplace safety.

In summary, the Baldor iMN1800 is a top-tier industrial motor drive that combines advanced motor control technology, energy efficiency, robust construction, and enhanced safety features. Its flexibility and connectivity make it a valuable asset for diverse industrial applications, ultimately driving operational efficiency and effectiveness.