LMPY Series Continued

Polynoid Linear Motor Holding Option Continued

Operation Considerations The motor must always be operated within the specified operating parameter limits. Exceeding those limits will permanently damage the motor.

Note: Rod should not support axial loads that can induce premature bearing failure.

The following steps must be completed to ensure safe and proper operation.

1.Verify that all electrical wiring and cables are properly connected. Refer to the manual provided with the control for this information.

2.If using a control, adjust the control continuous current limit to match the motor’s continuous current specifications.

3.Adjust the control peak current limit so it will not exceed the motor’s peak current specification.

Leadwire Connection

Motor Cable

Signal Name

Wire Color

Motor Phase A

Black

 

 

Motor Phase B

Red

 

 

Motor Phase C

White

Mounting Instructions Refer to the outline drawing (supplied with motor) for hole dimensions and mounting information. When attaching the payload to the motor, avoid axial loading of the motor shaft. Axial loading can damage the rulon bearing.

2-12 Installation & Operation