LMSS Series Linear Stepper

Roller Bearing Motor

InstallationPrior to placing the Forcer on the Platen both surfaces must be cleaned. Use this method:

1.Apply masking tape to lamination surface of the Forcer to remove any metallic contaminants.

2.Using alcohol, clean both surfaces to remove any adhesive residue and any other contaminants on the Forcer and the Platen.

Note: Apply small amount of alcohol to cloth for cleaning. Never pour or drip alcohol or other chemicals onto the forcer or platen surfaces.

 

3.

Wax and polish Platen and Forcer surfaces. ( Turtle Wax ). Remove any visible

 

 

residue.

Adjust Air Gap

Factory preset to 0.0015″ .

 

Note: When receiving the Forcer and the Platen, the air gap is already set to

 

 

0.0015″ . (Increasing the air gap will decrease the force). Use the following

 

 

instructions only if you need to reset the air gap.

 

1.

Carefully remove the Forcer from the platen by sliding off the Forcer of the end

 

 

of the Platen. (So as not to score the Forcer and the Platen surfaces).

 

2.

Loosen the four screws (1 turn) on the bearing kits using an Allen key.

 

3.

Center the shim on the toothed section of the Platen.

 

4.

Place the Forcer on the Platen. Be sure that the shim is only between the

 

 

Forcer and the Platen, and not between the wheels and the Platen.

 

5.

Apply downward pressure on both bearing kits only (the Forcer is attached

 

 

magnetically) and then tighten the four screws to 30 in–lbs of torque.

 

6.

Slide the Forcer down the Platen while holding the shim in place and remove

 

 

the shim.

Maintenance

Waxing of the Forcer lamination for corrosion protection is recommended every month (or

as needed) depending on environmental conditions (i.e. humidity and moisture).

Operation Considerations The motor must always be operated within the specified operating parameter limits. Exceeding those limits will permanently damage the motor.

The forcer must never touch the platen during operation. Equal horizontal and vertical air gap must be maintained.

The following steps must be completed to ensure safe and proper operation.

1.Verify that all electrical wiring and cables are properly connected. Refer to the manual provided with the control for this information.

2.Adjust the stepper driver current to match the motor’s current specification.

3.Strain relieve the wires prior to operating.

AY0165A00 Leadwire Connection (9 pin to flying leads)

Color

Pin#

Description

6

 

 

1

When a Male D Sub connector is used, use the pin numbers to connect the forcer.

 

 

White

1

A1+ Winding

 

 

 

 

2

 

 

2

N.C.

7

 

 

 

 

 

 

3

When flying leads are used, use the color codes to connect the forcer.

 

8

 

 

Green

3

B1+ Winding

 

 

4

9

 

 

 

 

4

N.C.

 

 

5

 

 

 

 

 

 

Black

5

Ground

 

 

 

 

 

 

6

N.C.

 

Male (D Sub)

 

Red

7

A1– Winding

 

 

 

 

 

 

8

N.C.

 

 

 

 

 

Orange

9

B1– Winding

 

 

 

 

 

MN1800

Installation & Operation 2-13

Page 20
Image 20
Baldor iMN1800 manual Lmss Series Linear Stepper, Roller Bearing Motor, Adjust Air Gap, Maintenance

iMN1800 specifications

The Baldor iMN1800 is a comprehensive industrial motor drive, engineered for a wide range of applications in various sectors such as manufacturing, robotics, and automation. This drive exemplifies Baldor's commitment to innovation, performance, and efficiency, offering users advanced features that cater to modern industrial demands.

At the heart of the iMN1800 is its state-of-the-art motor control technology, designed to provide precise control over motor speed and torque. This is achieved through a sophisticated algorithm that adjusts the motor's performance in real-time, ensuring reliability and efficiency. The iMN1800 is compatible with various forms of electric motors, including AC induction and permanent magnet synchronous motors, making it versatile for numerous applications.

One of the standout features of the Baldor iMN1800 is its energy efficiency. It complies with various energy standards, which not only helps reduce operational costs but also minimizes the environmental impact associated with industrial operations. With an impressive efficiency rating, the iMN1800 contributes to lower energy consumption, making it an economically viable solution for businesses aiming to enhance sustainability.

In terms of connectivity, the iMN1800 incorporates advanced communication protocols such as Ethernet/IP and Modbus, allowing for seamless integration into existing industrial networks. This feature facilitates real-time monitoring and control, empowering operators to make informed decisions based on live data. The user-friendly interface enables quick access to essential parameters for both configuration and diagnostics, ensuring ease of use for technicians and engineers alike.

Moreover, the iMN1800 is built with robust construction materials, ensuring durability in demanding environments. Its rugged design allows it to withstand harsh conditions, including high temperatures and vibrations, common in industrial settings. This reliability contributes to reduced downtime and maintenance costs, promoting a more productive work environment.

The Baldor iMN1800 also features advanced safety mechanisms, including overload protection and short-circuit protection, guaranteeing the safety of both personnel and equipment. These attributes align with modern safety standards, making it a trusted choice for industries that prioritize workplace safety.

In summary, the Baldor iMN1800 is a top-tier industrial motor drive that combines advanced motor control technology, energy efficiency, robust construction, and enhanced safety features. Its flexibility and connectivity make it a valuable asset for diverse industrial applications, ultimately driving operational efficiency and effectiveness.