5 DATA USED FOR POSITIONING CONTROL

MELSEC-Q

Setting item

Setting details

Cd.36

Step start information

During a step operation, this data item determines whether the operation is continued or restarted.

Cd.37

Skip command

To skip the current positioning operation, set "1" in this data item.

 

 

 

 

 

 

Cd.38

Teaching data selection

This data item specifies the teaching result write destination.

 

 

 

 

 

 

 

 

 

 

This data item specifies data to be produced by teaching.

 

 

 

 

If a value between 1 and 600 is set, a teaching operation is done.

 

 

Cd.39

Teaching positioning data No.

The value is cleared to "0" when the QD75 is initialized, when a teaching

 

 

 

 

 

 

 

 

 

operation completes, and when a illegal value (601 or higher) is entered.

 

 

 

 

 

 

 

 

 

 

This data item specifies the ABS moving direction carrying out the position control

 

 

Cd.40

ABS direction in degrees

 

 

when "degree" is selected as the unit.

 

 

 

 

 

 

 

 

 

 

 

 

5 - 130

Page 218
Image 218
Mitsubishi Electronics QD75P, QD75D user manual When degree is selected as the unit, Cd.39 Teaching positioning data No