AOC-USAS-L8i Add-on Card User’s Manual
9-10
Parameters –
<controller #> – Number of the SAS controller targeted by this command.
Program Return Value –
0x00 SUCCESS: command completed successfully.
0x01 FAILURE: command failed.
Sample Output –
Here is an example of the status information returned when a volume resynchronization
is in progress:
Background command progress status for controller 0...
IR Volume 1
Current operation : Synchronize
Volume ID : 6
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
Volume size (in sectors) : 70311936
Number of remaining sectors : 68250624
Percentage complete : 2.93%
Here is an example of the status information returned when no background volume
operation is in progress:
Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 6
Volume status : Enabled
Volume state : Optimal
Physical disk I/Os : Not quiesced
The status fields in the data displayed can have the following values:
Current operation – Synchronize or None
Volume status – Enabled or Disabled
Volume state – [Inactive] Optimal, Degraded, or Failed
Physical disk I/Os – Quiesced or Not quiesced
SETOFFLINE Command
NOTE: The SETOFFLINE command is supported by the DOS, Linux, and
WinPE versions of CFGGEN only.