<Setting>

Use Pr. 7 and Pr. 44 to set the acceleration time required to reach the frequency set in Pr. 20 from 0Hz.

Use Pr. 8 and Pr. 45 to set the deceleration time required to reach 0Hz from the frequency set in Pr. 20.

Pr. 44 and Pr. 45 are valid when the RT signal is on. (*)

Set "- - -" in Pr. 45 to make the deceleration time equal to the acceleration time (Pr. 44).

CAUTION

1.In S-shaped acceleration/deceleration pattern A (refer to page 71), the set time is the period required to reach the base frequency set in Pr. 3.

Acceleration/deceleration time calculation expression when the set frequency is the base frequency or higher

t =

4

×

T

 

× f 2 +

5

T

9

(Pr. 3)

2

9

 

 

 

 

 

T:Acceleration/deceleration time setting (s) f : Set frequency (Hz)

Guideline for acceleration/deceleration time at the base frequency of 60Hz (0Hz to set frequency)

Frequency setting (Hz)

 

 

 

60

120

Acceleration/

 

 

deceleration time (s)

 

 

5

5

12

 

 

 

15

15

35

2.If the Pr. 20 setting is changed, the settings of calibration functions Pr. 38 and Pr. 39 (frequency setting signal gains) remain unchanged.

To adjust the gains, adjust calibration functions Pr. 38 and Pr. 39.

3.When the setting of Pr. 7, Pr. 8, Pr. 44 or Pr. 45 is "0", the acceleration/ deceleration time is 0.04 seconds.

4.If the acceleration/deceleration time is set to the shortest value, the actual motor

acceleration/deceleration time cannot be made shorter than the shortest

 

acceleration/deceleration time which is determined by the mechanical system's J

 

(inertia moment) and motor torque.

2

*When the RT signal is on, the other second functions (Pr. 44, Pr. 45, Pr. 46, Pr. 47) are also selected.

Related parameters

Base frequency setting Pr. 3 "base frequency" (refer to page 59)

Acceleration/deceleration pattern, S-pattern acceleration/deceleration A

Pr. 29 "acceleration/deceleration pattern" (refer to page 71)

Calibration function Pr. 38 "frequency setting voltage gain frequency", Pr. 39 "frequency setting current gain frequency" (refer to page 74)

RT signal setting Pr. 60 to Pr. 63 (input terminal function selection) (refer to page 88) Jog acceleration/deceleration time Pr. 16 "jog acceleration/deceleration time"

(refer to page 67)

63

Page 72
Image 72
Mitsubishi FR - S500 instruction manual Frequency setting Hz 120 Acceleration Deceleration time s