2.15.3 PU contrast adjustment

By setting the communication parameter n15 "PU contrast adjustment", you can adjust the LCD contact of the parameter unit (FR-PU04). When using the FR-

PU04, adjust the numerical value to any brightness with the / keys and define that brightness with the WRITE key of the parameter unit.

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

n15 (991)

PU contrast adjustment

58

0 to 63

Setting is enabled when Pr. 30 = "1"

The parameter number in parentheses is the one for use of the parameter unit (FR-PU04).

CAUTION

When using the FR-PU04, you should press the WRITE key to store the LCD contrast setting.

2.15.4 PU main display screen data selection

You can choose the main display screen of the parameter unit (FR-PU04).

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

 

PU main display

 

 

 

n16 (992)

screen data

0

0, 100

Setting is enabled when Pr. 30 = "1"

 

selection

 

 

 

<Setting>

When you set 100 in n16, the monitor value changes depending on whether the inverter is at a stop or running.

 

 

n16

 

 

0

 

100

 

During operation/stop

During stop

During operation

Output frequency

Output frequency

Set frequency

Output frequency

Output current

 

Output current

 

Alarm display

 

Alarm display

 

REMARKS

During an error, the output frequency at error occurrence appears. During MRS, the values displayed are the same as during a stop.

Related parameters

Speed display Pr. 37 "speed display" (refer to page 73)

134

Page 143
Image 143
Mitsubishi FR - S500 instruction manual PU contrast adjustment, PU main display screen data selection, N16 100, During stop