1.6.3 Changing the control logic

The input signals are set to sink

NA and Japanese version

logic for the Japanese and NA

 

version, and to source logic for

 

the EC version.

 

To change the control logic, the

 

connector under the setting dial

 

must be moved to the other

 

position.

 

Change the connector position

EC version

using tweezers, a pair of long-

 

nose pliers etc.

 

Change the connector position

 

before switching power on.

 

CAUTION

Make sure that the front cover is installed securely.

The front cover is fitted with the capacity plate and the inverter unit with the rating plate. Since these plates have the same serial numbers, always replace the removed cover onto the original inverter.

The sink-source logic change-over connector must be fitted in only one of those positions. If it is fitted in both positions at the same time, the inverter may be damaged.