Pammeter List

Func- Pa- Indica- tion rame- tion ter

function

84 *

operation

85 *

 

Multi-speed

86 *

87 *

 

 

88

control

89 *

90 *

 

PID

91

92

 

93 *

 

94 *

compensation

95

96

 

Slip

97

Automatictorque boost

99

 

98

 

 

Minimum

Factory

Refer

Cus-

Name

Setting Range

Setting

tomer

 

 

Increments

Setting

To:

Setting

Multi-speed

 

 

 

 

 

setting (speed

0 to 120Hz, - - -

0.1Hz

- - -

61

 

12)

 

 

 

 

 

Multi-speed

 

 

 

 

 

setting (speed

0 to 120Hz, - - -

0.1Hz

- - -

61

 

13)

 

 

 

 

 

Multi-speed

 

 

 

 

 

setting (speed

0 to 120Hz, - - -

0.1Hz

- - -

61

 

14)

 

 

 

 

 

Multi-speed

 

 

 

 

 

setting (speed

0 to 120Hz, - - -

0.1Hz

- - -

61

 

15)

 

 

 

 

 

PID action

20: PID reverse action,

1

20

101

 

selection

21: PID forward action

 

 

 

 

 

PID

 

 

 

 

 

proportional

0.1 to 999%, - - -

0.1%

100%

101

 

band

 

 

 

 

 

PID integral

0.1 to 999s, - - -

0.1s

1s

101

 

time

 

 

 

 

 

 

PID upper limit

0 to 100%, - - -

0.1%

- - -

101

 

PID lower limit

0 to 100%, - - -

0.1%

- - -

101

 

PID action set

 

 

 

 

 

point for PU

0 to 100%

0.01%

0%

101

 

operation

 

 

 

 

 

PID differential

0.01 to 10s, - - -

0.01s

- - -

101

 

time

 

 

 

 

 

Rated motor

0 to 50%, - - -

0.01%

- - -

109

 

slip

 

 

 

 

 

 

Slip

 

 

 

 

 

compensation

0.01 to 10s

0.01s

0.5s

109

 

time constant

 

 

 

 

 

Constant-

 

 

 

 

 

output region

 

 

 

 

 

slip

0, - - -

1

- - -

109

 

compensation

 

 

 

 

 

selection

 

 

 

 

 

Automatic

 

 

 

 

 

torque boost

0.1 to 3.7kW, - - -

 

 

 

 

selection

(0.2 to 3.7kW, - - - for

0.01kW

- - -

109

 

(Motor

the 400V class.)

 

 

 

 

capacity)

 

 

 

 

 

Motor primary

0 to 50, - - -

0.01

- - -

111

 

resistance

 

 

 

 

 

52

Page 61
Image 61
Mitsubishi FR - S500 instruction manual Pid