4) Send data from computer to inverter during data read

[No data error detected]

 

 

 

 

[Data error detected]

 

(May be omitted)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format G

 

*3

Inverter

*4

 

 

 

 

Format H

 

*3

Inverter

*4

 

 

ACK

station

 

 

 

 

 

 

NAK

station

 

 

number

 

 

 

 

Number

 

number

 

 

1

2 3

4

 

 

 

1

2 3

4

 

 

 

 

of

 

 

 

 

characters

Number

of

characters

REMARKS

The inverter station numbers may be set between H00 and H1F (stations 0 and 31) in hexadecimal.

*3 indicates the control code.

*4 indicates the CR or LF code.

When data is transmitted from the computer to the inverter, codes CR (carriage return) and LF (line feed) are automatically set at the end of a data group on some computers. In this case, setting must also be made on the inverter according to the computer.

Also, the presence and absence of the CR and LF codes can be selected using n11.

At *5, when communication parameter n7 "waiting time setting" - - -, create the communication request data without "waiting time" in the data format.

(The number of characters is decremented by 1.)

(4) Data definitions

1) Control codes

Signal

ASCII Code

Description

STX

H02

Start of Text (Start of data)

ETX

H03

End of Text (End of data)

ENQ

H05

Enquiry (Communication request)

ACK

H06

Acknowledge (No data error detected)

LF

H0A

Line Feed

CR

H0D

Carriage Return

NAK

H15

Negative Acknowledge (Data error detected)

2)Inverter station number

Specify the station number of the inverter which communicates with the computer.

3)Instruction code

Specify the processing request, e.g. operation, monitoring, given by the computer to the inverter. Hence, the inverter can be run and monitored in various ways by specifying the instruction code as appropriate. (Refer to page 177.)

4)Data

Indicates the data such as frequency and parameters transferred to and from the inverter. The definitions and ranges of set data are determined in accordance with the instruction codes. (Refer to page 177.)