Mitsubishi FR - S500 Handling of the RS-485 Connector, Stall prevention, Frequency jump

Models: FR - S500

1 191
Download 191 pages 47.82 Kb
Page 7
Image 7

1.8.3 Current input selection "AU signal": Setting "4"

38

1.8.4 Start self-holding selection (STOP signal): Setting "5"

38

1.8.5 Output shut-off (MRS signal): Setting "6"

39

1.8.6 External thermal relay input: Setting "7"

39

1.8.7 Jog operation (JOG signal): Setting "9"

40

1.8.8 Reset signal: Setting "10"

40

1.8.9 PID control valid terminal: Setting "14"

41

1.8.10 PU operation/external operation switching: Setting "16"

41

1.9 Handling of the RS-485 Connector

 

 

(Type with RS-485 Communication Function)

41

1.10 Design Information

 

44

2. FUNCTIONS

 

 

45

2.1 Function (Parameter) List

 

46

2.2 List of Parameters Classified by Purpose of Use

56

2.3 Explanation of Functions (Parameters)

58

2.3.1 Torque boost

...........................................................................

58

2.3.2 Maximum and minimum frequency

59

2.3.3 Base frequency, Base frequency voltage

59

2.3.4 Multi-speed operation

to

to

....... 61

2.3.5 Acceleration/deceleration time

...................

62

2.3.6 Electronic overcurrent protection

64

2.3.7 DC injection brake

.........................................................

64

2.3.8 Starting frequency

...........................................................................

65

2.3.9 Load pattern selection

.....................................................................

66

2.3.10 Jog frequency

.......................................................................

67

2.3.11 RUN key rotation direction selection

67

2.3.12 Stall prevention function and current limit function

68

2.3.13 Stall prevention

............................................................

69

2.3.14 Acceleration/deceleration pattern

71

2.3.15 Extended function display selection

72

2.3.16 Frequency jump

to

72

2.3.17 Speed display

 

73

2.3.18 Biases and gains of the frequency setting voltage (current)

 

to

..........................................................................

74

2.3.19 Start-time ground fault detection selection

78

2.4 Output Terminal Function Parameters

78

2.4.1 Up-to-frequency sensitivity

78

2.4.2 Output frequency detection

79

2.5 Current Detection Function Parameters

80

2.5.1 Output current detection functions

80

2.5.2 Zero current detection

............................................................

81

2.6 Display Function Parameters

82

2.6.1 Monitor display

........................................................................

82

 

II

 

 

Page 7
Image 7
Mitsubishi FR - S500 instruction manual Handling of the RS-485 Connector, Stall prevention, Frequency jump, Monitor display