Mitsubishi FR - S500 Func- Parameter tion Number, Data Code Computer, Extension, Link Data, 7F/FF

Models: FR - S500

1 191
Download 191 pages 47.82 Kb
Page 186
Image 186

APPENDIX 1 PARAMETER DATA CODE LIST

Func- Parameter tion Number

 

0

 

1

 

2

 

3

functions

4

5

 

Basic

6

7

 

 

8

 

9

 

30

 

79

 

Data Code

Computer

Link Parameter

 

 

 

Extension

 

 

 

Link Data

Name

 

 

Setting

Read

Write

Setting

 

(Data Code

 

 

 

Increments *

 

 

 

7F/FF)

 

 

 

 

Torque boost

00

80

0.1%

0

Maximum frequency

01

81

0.01Hz

0

Minimum frequency

02

82

0.01Hz

0

Base frequency

03

83

0.01Hz

0

Multi-speed setting

04

84

0.01Hz

0

(high speed)

 

 

 

 

Multi-speed setting

05

85

0.01Hz

0

(middle speed)

 

 

 

 

Multi-speed setting

06

86

0.01Hz

0

(low speed)

 

 

 

 

Acceleration time

07

87

0.1s

0

Deceleration time

08

88

0.1s

0

Electronic thermal O/L

09

89

0.01A

0

relay

 

 

 

 

Extended function display

1E

9E

1

0

selection

 

 

 

 

Operation mode selection

4F

None

1

0

The extended function parameters are made valid by setting "1" in Pr. 30 "extended function display selection".

Func- Parameter tion Number

 

10

 

11

functions

12

14

 

13

operation

15

16

 

Standard

17

20

 

19

 

21

 

22

 

Data Code

Computer

Link Parameter

 

 

 

Extension

 

 

 

Link Data

Name

 

 

Setting

Read

Write

Setting

 

(Data Code

 

 

 

Increments *

 

 

 

7F/FF)

 

 

 

 

DC injection brake

0A

8A

0.01Hz

0

operation frequency

 

 

 

 

DC injection brake

0B

8B

0.1s

0

operation time

 

 

 

 

DC injection brake

0C

8C

0.1%

0

voltage

 

 

 

 

Starting frequency

0D

8D

0.01Hz

0

Load pattern selection

0E

8E

1

0

Jog frequency

0F

8F

0.01Hz

0

Jog acceleration/

10

90

0.1s

0

deceleration time

 

 

 

 

RUN key rotation

11

91

1

0

direction selection

 

 

 

 

Base frequency voltage

13

93

0.1V

0

Acceleration/deceleration

14

94

0.01Hz

0

reference frequency

 

 

 

 

Stall prevention function

15

95

1

0

selection

 

 

 

 

Stall prevention operation

16

96

0.1%

0

level

 

 

 

 

 

 

 

 

 

177

Page 186
Image 186
Mitsubishi FR - S500 Func- Parameter tion Number, Data Code Computer, Extension, Link Data, Read Write, 7F/FF