(2)3-phase 400V power supply

Japanese version

FR-S540-0.4K to 3.7K (-R) NA version

FR-S540-0.4K to 3.7K-NA (R) EC version

FR-S540-0.4K to 3.7K-EC (R)

Type FR-S540-K(-R)

Applicable motor capacity

kW

(*1)

 

HP

 

 

 

Output

Rated capacity (kVA) (*2)

Rated current (A)

 

 

Overload capacity (*3)

 

Voltage (*4)

 

Rated input AC (DC) voltage,

supply

frequency

fluctuation

Power

Permissible AC (DC) voltage

Permissible frequency

 

 

fluctuation

 

Power supply system

 

capacity (kVA) (*5)

Protective structure (JEM1030)

Cooling system

Approximate weight (kg (lbs))

0.4

0.75

1.5

2.2

3.7

0.4

0.75

1.5

2.2

3.7

1/2

1

2

3

5

0.9

1.6

2.7

3.7

5.9

1.1

2.1

3.5

4.8

7.7

 

 

 

 

 

150% 60s 200% 0.5s (Inverse time characteristics)

Three phase, 380V to 480V 50Hz/60Hz

Three phase, 380V to 480V 50Hz/60Hz

325 to 528V 50Hz/60Hz

± 5%

1.5

2.5

4.5

 

5.5

 

9.5

 

 

 

 

 

 

 

Enclosed type (IP20)

 

Self-cooling

 

Forced air cooling

 

1.5

1.5

1.5

 

1.6

 

1.7

(3.3)

(3.3)

(3.3)

 

(3.53)

 

(3.75)

 

 

 

 

 

 

 

*1. The applicable motor capacity indicated is the maximum capacity applicable when a Mitsubishi 4-pole standard motor is used.

*2. The rated output capacity indicated assumes that the output voltage is 440V.

*3. The % value of the overload capacity indicates the ratio of the overload current to the inverter's rated output current.

For repeated duty, allow time for the inverter to return to or below the temperatures under 100% load.

*4. The maximum output voltage cannot exceed the power supply voltage. The maximum output voltage may be set as desired below the power supply voltage. However, the PWM pulse voltage value of the inverter output side voltage remains unchanged at about 2 that of the power supply.

*5. The power supply capacity changes with the values of the power supply side inverter impedances (including those of the input reactor and cables).