Mitsubishi FR - S500 instruction manual Function Parameter List

Models: FR - S500

1 191
Download 191 pages 47.82 Kb
Page 55
Image 55

Pammeter List

2.1 Function (Parameter) List

 

 

 

 

Minimum

Factory

 

Cus-

Parameter

Indica-

Name

Setting

Setting

Refer

tion

Range

Setting

<EC

To:

tomer

 

 

Increments

Setting

 

 

 

 

version>

 

 

 

 

 

 

6%/5%/

 

 

0

 

Torque boost

0 to 15%

0.1%

4%

58

 

 

 

 

 

 

(Note 1)

 

 

1

 

Maximum frequency

0 to 120Hz

0.1Hz

60Hz

59

 

 

<50Hz>

 

 

 

 

 

 

 

 

2

 

Minimum frequency

0 to 120Hz

0.1Hz

0Hz

59

 

3

 

Base frequency

0 to 120Hz

0.1Hz

60Hz

59

 

 

<50Hz>

 

 

 

 

 

 

 

 

4 *

 

Multi-speed setting

0 to 120Hz

0.1Hz

60Hz

61

 

 

(high speed)

<50Hz>

 

 

 

 

 

 

 

5 *

 

Multi-speed setting

0 to 120Hz

0.1Hz

30Hz

61

 

 

(middle speed)

 

 

 

 

 

 

 

 

6 *

 

Multi-speed setting

0 to 120Hz

0.1Hz

10Hz

61

 

 

(low speed)

 

 

 

 

 

 

 

 

7

 

Acceleration time

0 to 999s

0.1s

5s

62

 

8

 

Deceleration time

0 to 999s

0.1s

5s

62

 

 

 

Electronic thermal O/L

 

 

Rated

 

 

9

 

0 to 50A

0.1A

output

64

 

 

 

relay

 

 

current

 

 

 

 

 

 

 

 

 

30 *

 

Extended function

0, 1

1

0

72

 

 

display selection

 

 

 

 

 

 

 

 

79

 

Operation mode

0 to 4, 7, 8

1

0

98

 

 

selection

 

 

 

 

 

 

 

 

Note 1: The factory setting varies with the inverter capacity: 5% for FR-S540-1.5K and 2.2K, 4% for FR-S540-3.7K.

The extended function parameters are made valid by setting "1" in Pr. 30 "extended function display selection". (For full information on the way to set Pr. 30, refer to the instruction manual (basic).)

Func-

Pa-

Indica-

 

 

Minimum

Factory Refer

Cus-

rame-

Name

Setting Range

Setting

tomer

tion

ter

tion

 

 

Increments

Setting

To:

Setting

 

 

 

DC injection

 

 

 

 

 

 

10

 

brake

0 to 120Hz

0.1Hz

3Hz

64

 

 

 

operation

 

 

 

 

 

 

 

 

 

functions

 

 

frequency

 

 

 

 

 

 

 

 

DC injection

 

 

 

 

 

 

11

 

brake

0 to 10s

0.1s

0.5s

64

 

operation

13

 

operation time

0 to 60Hz

0.1Hz

0.5Hz

65

 

 

12

 

DC injection

0 to 15%

0.1%

6%

64

 

 

 

brake voltage

 

 

 

 

Starting

 

 

 

 

 

Standard

 

 

frequency

 

 

 

 

 

 

 

 

0: For constant-torque

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

loads,

 

 

 

 

 

14

 

Load pattern

1: For variable-torque

1

0

66

 

 

 

selection

loads,

 

 

 

 

 

 

 

 

2:For vertical lift loads,

3:For vertical lift loads

46

Page 55
Image 55
Mitsubishi FR - S500 instruction manual Function Parameter List