2.6 Display Function Parameters

2.6.1 Monitor display

You can choose the display of the operation panel "monitor/frequency setting screen".

For the Pr. 54 function, the Japanese version has the FM terminal feature, and the NA and EC versions have the AM terminal feature.

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

 

Operation panel

 

0, 1,

 

52

display data

0

 

100

 

 

selection

 

Setting is enabled when Pr. 30 = "1"

 

 

 

54

FM (AM) terminal

0

0, 1

 

function selection

 

 

 

 

 

POINT

You can also use the SET key to change the display. (Refer to the instruction

manual (basic) for the operation procedure.)

The pulse train output terminal FM (analog voltage output terminal AM) is available for signal output. (Make selection using the Pr. 54 "FM (AM) terminal function selection" value.)

<Setting>

 

 

Parameter Setting

 

Signal Type

Unit

Pr. 52

Pr. 54

Full-Scale Value of FM

Operation panel

FM (AM)

(AM) Level Meter

 

 

 

 

LED

terminal

 

Output

Hz

0/100

0

Pr. 55 "frequency monitoring

frequency

reference"

 

 

 

Output current

A

1

1

Pr. 56 "current monitoring

reference"

 

 

 

 

When "100" is set in Pr. 52, the monitor value changes depending on whether the inverter is during stop or running.

 

 

Pr. 52

 

 

0

 

100

 

During running/stop

During stop

During running

Output frequency

Output frequency

Set frequency

Output frequency

REMARKS

During an error, its definition appears.

During reset, the values displayed are the same as during a stop.

For selection of the parameter unit (FR-PU04) monitor display, refer to the communication parameter n16 "PU main display screen data selection". (Page 134)

CAUTION

The unit displayed on the operation panel is only A and other units are not displayed.

Related parameters

Speed display Pr. 37 "speed display" (refer to page 73)

Adjustment of FM (AM) level meter full-scale value Calibration parameter C1 "FM (AM) terminal calibration" (refer to page 111)

Monitoring reference Pr. 55 "frequency monitoring reference", Pr. 56 "current monitoring reference" (refer to page 84)

82