Mitsubishi FR - S500 Error Code List, 128, Description Data, Digits, Error Definition

Models: FR - S500

1 191
Download 191 pages 47.82 Kb
Page 137
Image 137

 

 

 

Instruction

 

Number

No.

Item

 

Description

of Data

 

Code

 

 

 

 

Digits

 

 

 

 

 

 

 

 

 

H00 to H6C and H80 to HEC parameter values

 

 

 

 

 

are changed.

 

 

Link

Read

H7F

H00: Pr. 0 to Pr. 99 are accessible.

 

 

H01: Communication parameter n13 (Pr. 145) and

 

11

parameter

 

 

calibration parameters C1 to C7 (Pr. 900 to

2 digits

expansion

 

 

Pr. 905) are accessible.

 

setting

 

 

H03: Communication parameters n1 to n12

 

 

 

 

 

 

 

Write

HFF

(Pr. 331 to Pr. 342) are accessible.

 

 

 

H09: Communication parameters n14 to n17

 

 

 

 

 

(Pr. 990 to Pr. 993) are accessible.

 

 

 

 

 

When setting the bias/gain (data codes H5E to

 

 

 

Read

H6C

H61, HDE to HE1) parameters

 

 

Second

H00: Frequency (*1)

 

 

 

 

H01: Analog

 

 

parameter

 

 

 

 

 

 

H02: Analog value of terminal (*2)

 

12

changing

 

 

2 digits

 

 

*1. The gain frequencies may also be written using

 

(Code

 

 

 

 

 

 

Pr. 38 and Pr. 39 (data codes A6 and A7).

 

 

HFF = 1)

 

 

 

 

Write

HEC

*2. When a voltage is given to the external

 

 

 

 

 

 

 

 

terminal to make bias or gain calibration, the

 

 

 

 

 

data value written is 4 digits.

 

REMARKS

For the instruction codes HFF, HEC, their set values are held once they are written, but changed to 0 when the inverter is reset or all clear is performed.

<Error Code List>

The corresponding error code in the following list is displayed if an error is detected in any communication request data from the computer:

Error

Item

Definition

Inverter

Code

Operation

 

 

 

Computer

The number of errors consecutively detected in

 

H0

communication request data from the computer is

 

NAK error

 

 

greater than allowed number of retries.

Brought to an

 

 

H1

Parity error

The parity check result does not match the specified parity.

alarm stop

H2

Sum check

The sum check code in the computer does not match

(OPT) if error

error

that of the data received by the inverter.

occurs

 

 

Protocol

Data received by the inverter is in wrong protocol, data

continuously

H3

receive is not completed within given time, or CR and

more than the

error

 

LF are not as set in the parameter.

allowable

 

 

H4

Framing

The stop bit length is not as specified by initialization.

number of

error

retries.

 

 

H5

Overrun

New data has been sent by the computer before the

 

error

inverter completes receiving the preceding data.

 

 

 

H6

———

———

———

 

 

 

Does not accept

H7

Character

The character received is invalid (other than 0 to 9, A to

received data but

error

F, control code).

is not brought to

 

 

 

 

alarm stop.

H8

———

———

———

H9

———

———

———

HA

Mode error

Parameter write was attempted in other than the computer

Does not accept

link operation mode or during inverter operation.

 

 

 

received data

HB

Instruction

 

The specified command does not exist.

but is not

code error

 

 

brought to alarm

 

Data range

Invalid data has been specified for parameter write,

HC

stop.

error

frequency setting, etc.

 

 

HD

———

———

———

HE

———

———

———

HF

———

———

———

128

Page 137
Image 137
Mitsubishi FR - S500 instruction manual Error Code List, 128, Description Data, Digits, Error Definition