Mitsubishi FR - S500 Reverse rotation prevention selection, Operation mode selection

Models: FR - S500

1 191
Download 191 pages 47.82 Kb
Page 107
Image 107

2.10.9 Reverse rotation prevention selection

This function can prevent any reverse rotation fault resulting from the incorrect input of the start signal.

POINT

Used for a machine which runs only in one direction, e.g. fan, pump. (The setting of this function is valid for the combined, PU, external and communication operations.)

Parameter

Name

Factory

Setting

Remarks

Setting

Range

 

 

 

 

Reverse rotation

 

 

 

78

prevention

0

0, 1, 2

Setting is enabled when Pr. 30 = "1"

 

selection

 

 

 

<Setting>

Pr. 78 Setting

Function

0Both forward and reverse rotations allowed

1Reverse rotation disallowed

2Forward rotation disallowed

2.10.10 Operation mode selection

Used to select the operation mode of the inverter.

The inverter can be run from the control panel or parameter unit (PU operation), with external signals (external operation), or by combination of PU operation and external operation (external/PU combined operation).

The inverter is placed in the external operation mode at power-on (factory setting).

Parameter

Name

Factory Setting

Setting Range

79

Operation mode selection

0

0 to 4, 7, 8

98

Page 107
Image 107
Mitsubishi FR - S500 instruction manual Reverse rotation prevention selection, Operation mode selection