Operation Panel Indication

PS

 

FR-PU04

PS

 

 

 

 

 

Name

PU stop (Stopped with PU STOP key)

 

Pr. 75 "reset selection/PU stop selection" had been set and a stop

Description

was made by pressing the

RESETSTOP key of the operation panel or

parameter unit (FR-PU04) during operation in the external

 

 

operation mode.

 

 

Check point

Check for a stop made by pressing the RESETSTOP key of the

operation panel during external operation.

 

Corrective action

Refer to page 94.

 

 

Operation Panel Indication

UV

 

 

 

 

Name

Undervoltage

 

If the power supply voltage of the inverter reduces, the control

 

circuit will not operate properly and will result in decreased motor

 

torque or increased heat generation. To prevent this, if the power

Description

supply voltage reduces below about 115VAC (about 230VAC for

 

the three-phase 400V power input series, about 58VAC for the

 

single-phase 100V power input series), this function stops the

 

inverter output.

 

Check for a start of large-capacity motor.

Check point

Check that the power supply capacity is as indicated in the

 

specifications (refer to page 161).

Corrective action

Check the power supply system equipment such as the power

supply.

 

(4) Write errors

Operation Panel Indication

Er1

 

FR-PU04

Control Mode

 

 

 

 

 

Name

Write disable error

 

 

 

Write was performed with "1" (write disable) set in Pr. 77

 

"parameter write disable selection".

Description

Frequency jump setting range overlapped.

Parameter write was performed though the operation panel does

 

 

not have the write precedence. (Only the type having RS-485

 

communication function)

 

 

 

Check the setting of Pr. 77 "parameter write disable selection".

 

(Refer to page 97)

 

 

 

Check the settings of Pr. 31 to 36 (frequency jump). (Refer to

Corrective action

page 72)

 

 

When the FR-PU04 is fitted and n17 = "0" or "1", the operation

 

 

of the operation panel is invalid.

 

For RS-485 connector (RS-485) communication, the operation

 

of the operation panel is invalid.

143