(1) How to make a restart after a stop by the

RESETSTOP

key input from the

 

operation panel (Restarting method with

 

shown)

1)

After completion of deceleration to

 

Speed

 

 

 

 

a stop, switch off the STF or STR

 

 

 

 

 

signal.

 

 

 

 

 

Time

 

 

PU

 

 

 

 

PU

2)

Press the

 

 

 

 

key

EXT key to

 

Control panel

 

EXT

 

show PU. ........ (

 

RESETSTOP

 

 

 

canceled)

STF

ON

key

 

 

 

PU

 

 

 

 

3)

Press the

 

(STR) OFF

 

 

 

EXT key to return to EXT.

 

 

 

4)Switch on the STF or STR signal. Stop and restart example for external operation

REMARKS

By entering the reset signal (RES) during operation, the inverter shuts off its output while it is reset, the internal thermal summation value of the electronic overcurrent protection and the number of retries are reset, and the motor coasts.

The Pr. 75 value can be set any time. Also, if parameter (all) clear is executed, this setting will not return to the initial value.

When the inverter is stopped by the PU stop function, the display alternates between and . An alarm is not output.

(2)How to make a restart when a stop is made by the input from the PU

STOP RESET key

1)After completion of deceleration to a stop, switch off the STF or STR signal.

2)

Press the EXT

key

 

. ..................... (

canceled)

3)

Switch on the STF or STR signal.

 

Speed

 

 

Time

 

 

 

 

Control panel

 

EXT

key

 

 

 

STF

ON

STOP

key

 

RESET

 

(STR) OFF

 

 

 

Stop and restart example for external operation

Besides the above operations, a restart can be made by performing a power-on reset

 

or resetting the inverter with the inverter's reset terminal.

2

 

REMARKS

By entering the reset signal (RES) during operation, the inverter shuts off output while it is reset, the data of the electronic overcurrent protection and regenerative brake duty are reset, and the motor coasts.

To resume operation, reset the inverter after confirming that the PU is connected securely.

The Pr. 75 value can be set any time. Also, if parameter (all) clear is executed, this setting will not return to the initial value.

When the inverter is stopped by the PU stop function, PS is displayed but an alarm is not output.