Data Code

Computer

 

 

 

 

 

Func-

Parameter

Name

 

 

Link Data

tion

Number

Read

Write

Setting

 

 

 

 

 

 

Increments *

 

C1 (900

FM (AM) terminal

5C

DC

 

(901))

calibration

 

 

 

 

 

C2 (902)

Frequency setting

5E

DE

0.01Hz

parameters

voltage bias frequency

C4 (903)

Frequency setting

5F

DF

0.1%

 

C3 (902)

Frequency setting

5E

DE

0.1%

 

voltage bias

Calibration

C6 (904)

voltage gain

60

E0

0.1%

bias

 

C5 (904)

Frequency setting current

60

E0

0.01Hz

 

bias frequency

 

 

Frequency setting current

 

 

 

 

C7 (905)

Frequency setting current

61

E1

0.1%

 

gain

 

C8 (269)

Parameter set by manufacturer. Do not set.

Link Parameter

Extension

Setting

(Data Code

7F/FF)

1

1

(6C/EC=0)

1

(6C/EC=1)

1

(6C/EC=1)

1

(6C/EC=0)

1

(6C/EC=1)

1

(6C/EC=1)

Clear parameters

CLr

Parameter clear

FC

1

 

 

 

 

 

 

 

 

 

ECL

Alarm history clear

F4

1

 

 

 

 

 

 

 

 

n1 (331)

Communication station

1F

9F

1

3

 

number

 

n2 (332)

Communication speed

20

A0

1

3

 

n3 (333)

Stop bit length

21

A1

1

3

 

n4 (334)

Parity check

22

A2

1

3

 

presence/absence

parameters

n7 (337)

Number of

25

A5

1

3

Wait time setting

 

n5 (335)

communication retries

23

A3

1

3

 

n6 (336)

Communication check

24

A4

0.1s

3

 

time interval

Communication

 

 

 

 

 

 

n8 (338)

Operation command write

26

A6

1

3

 

n9 (339)

Speed command write

27

A7

1

3

 

n10 (340)

Link start mode selection

28

A8

1

3

 

n11 (341)

CR/LF selection

29

A9

1

3

 

n12 (342)

E2PROM write selection

2A

AA

1

3

 

n13 (145)

PU display language

2D

AD

1

1

 

n14 (990)

PU buzzer sound control

5A

DA

1

9

 

n15 (991)

PU contrast adjustment

5B

DB

1

9

 

n16 (992)

PU main display screen

5C

DC

1

9

 

data selection

 

n17 (993)

PU disconnection

5D

DD

1

9

 

detection/PU setting lock

The parameter numbers within parentheses are those for use of the parameter unit (FR-PU04).

* Though parameter setting by RS-485 communication can be made in the setting increments indicated in the table, note that the valid setting increments are as indicated in the parameter list (page 46).

181

Page 190