Mitsubishi FR - S500 Description of I/O Terminal Specifications, Main circuit, Control circuit

Models: FR - S500

1 191
Download 191 pages 47.82 Kb
Page 18
Image 18

1.4 Description of I/O Terminal Specifications

1.4.1 Main circuit

Symbol

Terminal Name

Description

R, S, T *

AC power input

Connect to the commercial power supply.

<L1, L2, L3>

 

 

U, V, W

Inverter output

Connect a three-phase squirrel-cage motor.

N<->

DC voltage

DC voltage common terminal. Not isolated from the

common

power supply and inverter output.

 

 

 

 

 

 

 

 

 

 

Power factor

Disconnect the jumper from terminals P<+>-P1 and

P<+>, P1

improving DC

connect the optional power factor improving DC reactor

reactor connection

(FR-BEL). (The single-phase 100V power input model

 

 

 

 

 

 

 

 

 

 

 

cannot be connected.)

 

 

 

 

 

Earth (Ground)

For grounding the inverter chassis. Must be earthed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*R, S <L1, N> terminals for single-phase power input.

CAUTION

<>Terminal names in parentheses are those of the EC version.

1.4.2 Control circuit

 

Symbol

Terminal Name

Description

 

 

 

 

Forward rotation

Turn on the STF signal

When the STF and STR

 

 

STF

to start forward rotation

signals are turned on

 

 

start

 

 

 

and turn it off to stop.

simultaneously, the stop

 

input

 

 

 

 

 

Reverse rotation

Turn on the STR signal

command

 

 

 

STR

to start reverse rotation

is given.

 

 

 

start

Input terminal

 

Contact

 

and turn it off to stop.

 

 

 

 

 

function selection

 

 

 

Turn on the RH, RM and RL signals

 

 

 

(Pr. 60 to Pr. 63)

 

 

 

 

in appropriate combinations to select

 

 

RH

Multi-speed

changes the

 

 

RM

multiple speeds.

 

terminal functions.

 

 

selection

The priorities of the speed commands

 

 

RL

(*4)

 

 

 

 

are in order of jog, multi-speed setting

 

 

 

 

 

(RH, RM, RL, REX) and AU.

 

 

SD

 

Contact input

Common terminal for contact inputs

(terminals STF, STR,

 

 

RH, RM, RL) and indicator connection (terminal FM).

 

(*1)

 

common (sink)

 

 

Isolated from terminals 5 and SE.

 

 

 

 

 

 

signals

 

 

common

When connecting the transistor output (open collector

 

 

output to this terminal to prevent a malfunction caused by

 

 

 

External

output), such as a programmable controller (PLC),

 

 

 

transistor

connect the positive external power supply for transistor

Input

PC

 

24VDC power

undesirable current.

 

 

(*1)

 

 

 

 

supply

This terminal can be used as a 24V 0.1A DC power

 

 

 

 

 

 

 

 

Contact input

output across terminals PC-SD.

 

 

 

 

common (source)

When source logic is selected, this terminal serves as a

 

 

 

 

contact input signal common.

 

10Frequency setting 5VDC. Permissible load current 10mA. power supply

 

 

 

 

By entering 0 to 5VDC (0 to 10VDC), the maximum

 

setting

 

Frequency

output frequency is reached at 5V (10V) and I/O are

 

2

setting

proportional. Use Pr. 73 "0-5V/0-10V selection" to switch

 

 

 

(Voltage signal)

between 5V and 10V.

 

Frequency

 

(Current signal)

Input resistance 10k. Maximum permissible voltage 20V.

 

 

Set the AU signal in any of Pr. 60 to Pr. 63 (input

 

 

 

 

Enter 4-20mADC. This signal is factory-adjusted to reach

 

 

 

Frequency

0Hz at 4mA and 60Hz at 20mA. Maximum permissible

 

 

 

input current 30mA. Input resistance approximately 250.

 

 

4

setting

 

 

For current input, turn on the signal AU.

 

 

 

 

 

 

 

 

terminal function selection).

1

9

Page 18
Image 18
Mitsubishi FR - S500 instruction manual Description of I/O Terminal Specifications, Main circuit, Control circuit