3)FR-S520S-0.1K to 1.5K (-R) FR-S520S-0.2K to 1.5K-EC (R)

 

 

 

 

Power

Power

Cables (mm2)

Motor

 

Rated current of

Magnetic

Factor

Factor

(*2)

 

Circuit Breaker

Contactor

Improving

Improving

 

 

Output

Inverter

 

 

(Refer to

(MC)

AC Reactor

DC Reactor

 

 

(kW

Model

R, S

 

page 15)

(Refer to

(Refer to

(Refer to

U, V, W

(HP))

 

<L1, N>

 

 

(*1)

page 17)

page 18)

page 18)

 

 

 

 

 

 

(*3)

(*3)

 

 

0.1

FR-S520S-

30AF/5A

S-N10

FR-BAL-0.4K

FR-BEL-0.4K

2

2

(1/8)

0.1K

 

 

 

 

 

 

0.2

FR-S520S-

30AF/10A

S-N10

FR-BAL-0.4K

FR-BEL-0.4K

2

2

(1/4)

0.2K

 

 

 

 

 

 

0.4

FR-S520S-

30AF/10A

S-N20

FR-BAL-

FR-BEL-

2

2

(1/2)

0.4K

0.75K

0.75K

 

 

 

 

0.75

FR-S520S-

30AF/15A

S-N20

FR-BAL-1.5K

FR-BEL-1.5K

2

2

(1)

0.75K

 

 

 

 

 

 

1.5

FR-S520S-

30AF/20A

S-N21

FR-BAL-2.2K

FR-BEL-2.2K

2

2

(2)

1.5K

 

 

 

 

 

 

4)FR-S510W-0.1K to 0.75K (-R) FR-S510W-0.1K to 0.75K-NA

 

 

 

 

Power

Power

Cables (mm2)

Motor

 

Rated current of

Magnetic

Factor

Factor

(*2)

 

Circuit Breaker

Contactor

Improving

Improving

 

 

Output

Inverter

 

 

(Refer to

(MC)

AC Reactor DC Reactor

 

 

(kW

Model

R, S

 

page 15)

(Refer to

(Refer to

(Refer to

U, V, W

(HP))

 

<L1, N>

 

 

(*1)

page 17)

page 18)

page 18)

 

 

 

 

 

 

(*3)

(*4)

 

 

0.1

FR-S510W-

30AF/10A

S-N10

FR-BAL-

−−

2

2

(1/8)

0.1K

0.75K

 

 

 

 

 

0.2

FR-S510W-

30AF/15A

S-N10

FR-BAL-1.5K

−−

2

2

(1/4)

0.2K

 

 

 

 

 

 

0.4

FR-S510W-

30AF/20A

S-N20

FR-BAL-2.2K

−−

2

2

(1/2)

0.4K

 

 

 

 

 

 

0.75

FR-S510W-

30AF/30A

S-N20

FR-BAL-3.7K

−−

3.5

2

(1)

0.75K

 

 

 

 

 

 

*1 For installations in the United States or Canada, the circuit breaker must be inverse time or instantaneous trip type.

*2 The size of the cables assume that the wiring length is 20m (65.62feet).

*3 The power factor may be slightly less.

*4 The single-phase 100V power input model does not allow the power factor improving DC reactor to be fitted.

14