Pammeter List

Func- Pa- Indica- tion rame- tion ter

 

60

 

61

 

62

 

63

 

64

selectionfunction

65

66

 

Terminal

67

 

68

69

70*

71

72*

73

 

 

Minimum

Factory

Refer

Cus-

Name

Setting Range

Setting

tomer

 

 

Increments

Setting

To:

Setting

RL terminal

0: RL, 1: RM, 2: RH,

 

 

 

 

function

1

0

88

 

3: RT, 4: AU, 5: STOP,

 

selection

 

 

 

 

RM terminal

6: MRS, 7: OH,

 

 

 

 

function

8: REX, 9: JOG,

1

1

88

 

selection

 

 

 

 

10: RES, 14: X14,

 

 

 

 

RH terminal

 

 

 

 

16: X16,

 

 

 

 

function

1

2

88

 

selection

- - -: STR (May be

 

 

 

 

STR terminal

assigned to the STR

 

 

 

 

function

terminal only)

1

- - -

88

 

selection

 

 

 

 

 

 

 

 

 

RUN terminal

 

 

 

 

 

function

0: RUN, 1: SU, 3: OL,

1

0

90

 

selection

4: FU, 11: RY, 12: Y12,

 

 

 

 

A, B, C

13: Y13, 14: FDN,

 

 

 

 

terminal

15: FUP, 16: RL,

1

99

90

 

function

98: LF, 99: ABC

 

 

 

 

 

selection

 

 

 

 

 

 

0: OC1 to 3, OV1 to 3,

 

 

 

 

 

THM, THT, GF,

 

 

 

 

Retry selection

OHT, OLT, PE, OPT

1

0

91

 

1: OC1 to 3,

 

 

2: OV1 to 3,

 

 

 

 

 

3: OC1 to 3, OV1 to 3

 

 

 

 

 

0: No retry

 

 

 

 

 

1 to 10:

 

 

 

 

Number of

Without alarm output

 

 

 

 

retries at alarm

during retry operation

1

0

91

 

occurrence

101 to 110:

 

 

 

 

 

With alarm output

 

 

 

 

 

during retry operation

 

 

 

 

Retry waiting

0.1 to 360s

0.1s

1s

91

 

time

 

 

 

 

 

 

Retry count

0: Cumulative count

1

0

91

 

display erase

erase

 

 

 

 

 

Soft-PWM

0: Soft-PWM invalid,

1

1

92

 

setting

1: Soft-PWM valid

 

 

 

 

 

 

0: Thermal characteristic

 

 

 

 

 

for standard motor

 

 

 

 

Applied motor

1: Thermal characteristic

1

0

93

 

 

for Mitsubishi

 

 

 

 

 

constant-torque motor

 

 

 

 

PWM

 

 

 

 

 

frequency

0 to 15

1

1

92

 

selection

 

 

 

 

 

0-5V/0-10V

0: For 0 to 5VDC input

1

0

93

 

selection

1: For 0 to 10VDC input

 

 

 

 

 

50

Page 59
Image 59
Mitsubishi FR - S500 instruction manual Thm, Tht, Gf, Oht, Olt, Pe, Opt, Pwm