Blodgett CNV14G Installation, Owner’s Responsibilities, Maximum shelf loading -- 100 lbs 45.5 Kg

Models: CNV14E CNV14G

1 53
Download 53 pages 52.63 Kb
Page 8
Image 8
Installation

Installation

Owner’s Responsibilities

Installation responsibilities prior to service startup inspection

You are entitled to a free start-up inspection ser- vice by our factory ASAP. Before a factory repre- sentative arrives to perform a startup procedure, the owner must already have satisfied the follow- ing requirements.

1.Oven(s) are uncrated, stacked (if applies) and put in place.

NOTE: Please refer to Leg Attachment and Stacking.

Maximum shelf loading -- 100 lbs (45.5 Kg)

 

RATINGS --

GAS APPLIANCES --

CNV14G/AA

 

 

 

 

 

 

 

Gas Type

Gas Input

 

Voltage

Phase

Amps

Motor

 

 

 

 

 

 

 

U.S. and Canadian Installations

 

 

 

 

 

 

 

 

 

 

 

 

Natural

65,000 BTU/Hr

 

208-240

1

15

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

 

120

1

15

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

Propane

65,000 BTU/Hr

 

208-240

1

15

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

 

120

1

15

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

3/4” FNPT connector for all U.S. and Canadian installations

 

 

--RATINGS

--ELECTRIC APPLIANCES CNV14E/AA

 

 

 

 

 

 

 

 

 

Voltage

Hz

 

Phase

 

Max Load (amps)

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

L2

L3

 

 

 

 

 

 

 

 

 

 

208

60

 

1

 

89

89

---

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

208

60

 

3

 

52

52

52

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

240

60

 

1

 

82

82

---

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

240

60

 

3

 

47

47

47

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

480

60

 

3

 

23

23

23

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

380/220

50

 

3

 

25

25

25

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

415/240

50

 

3

 

27

27

27

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

400/230

50

 

3

 

26

26

26

1/2HP 208-240VAC, 50/60 Hz

 

 

 

 

 

 

 

 

 

4

Page 8
Image 8
Blodgett CNV14G Owner’s Responsibilities, Installation responsibilities prior to service startup inspection, Ratings