Installation
Electrical Connections
All Models
NOTE: Electrical connections must be performed by a qualified installer only.
Before making any electrical connections to these appliances, check that the power supply is ade- quate for the voltage, amperage, and phase require- ments stated on the rating name plate mounted on the appliance.
The circuit breaker that is used to provide power to this appliance must have a minimum of .076” (3mm) contact spacing. The circuit breaker must meet all Local and National installation standards.
All appliances must be installed in accordance with Local or National Electrical codes.
A wiring schematic is located on the inside of the removeable side panel.
NOTE: Disconnect the power supply to the ap- pliance before servicing.
WARNING!!
Improper installation will invalidate your warranty.
Electric Models
A strain relief for the power supply cord is required. The installer must supply a cord bushing that meets all Local and National installation standards.
Gas Models
U.S. and Canadian Installations
A power cord (115V or 230V) is supplied with a plug attached. Plug the power cord into the de- sired receptacle.
Export Installations
A 230V 13 amp fused power cord is supplied with a plug attached. Plug the power cord into the ap- propriate receptacle.
See Figure 8 for power cord routing and connec- tions to the line filter.
WARNING!!
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its ser- vice agent.
| Power Connections | Line Filter | |
|
| ||
| Line Filter |
| |
|
| L1 | |
|
| Brown wire | |
| Line Filter |
| |
| Mounting Bracket |
| |
| Power Cord with | N | |
| Blue wire | ||
Strain Relief | 13 amp fuse | ||
| |||
| Ground Symbol | ||
|
| ||
|
| Green/Yellow wire | |
Rear view of BC14G | Export Installations | ||
with rear panel removed |
Figure 8
10