Installation
Final Check Lists
WARNING!!
Final check list must be performed by a qualified installer only.
ELECTRICAL CONTROL COMPARTMENT
jVoltage to appliance matches rating plate
PLUMBING FINAL CHECK -- CNV14E ONLY
jIncoming water pressure within appliances of specification
jAtmospheric vented drain in place
jWater solenoid properly bracketed and not leaking
jWater feed lines intact without leaks
j Optional Spray Hose connected properly. Connect the optional spray hose to the fill so- lenoid as shown.
Cold Water Supply
Hose and Spray
Option
OVEN OPERATIONAL TESTS
NOTE: Checks to be made by customer or autho- rized service agent.
Cool Down Mode
jCheck that the fan runs with the door open.
Hot Air Mode
Turn to HOT AIR mode and set thermostat to
400_F (204_C) and verify:
jHeat demand light is on j Oven is heating properly
jHeat lights shuts off at 400_F (204_C) and oven maintains 400_F (204_C).
jFan shuts off with door open.
To
Oven Fill
Manifold
Figure 11
15