Section 1A/Folio E60-20

SPECPLUS SPS2GFSVA26U

Page 2 of 2

2'x2' RECESSED FLUORESCENT, LENS FRAME TROFFER, STATIC, 2 LAMP, T8 OR T12

PHOTOMETRY

MODEL NO. SPS2GFSVA26U

 

 

Luminaire Efficacy Rating

 

 

 

LER-58.6 Watts-56.3 BF-0.87

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

RF

 

20

 

 

20

 

 

20

 

 

RC

 

80

 

 

50

 

 

30

 

 

RW

70

50

30

50

30

10

50

30

10

 

1

79

75

73

71

69

67

68

66

65

ratio

2

72

67

62

63

59

56

61

58

55

3

66

59

54

56

52

48

54

51

47

cavity

4

61

53

47

50

46

42

49

45

41

5

56

48

42

45

40

37

44

40

36

room

6

52

43

37

41

36

32

40

36

32

7

49

39

33

38

33

29

37

32

29

 

8

45

36

30

35

30

26

34

29

26

 

9

42

33

28

32

27

24

31

27

23

 

10

40

31

25

30

25

21

29

25

21

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

room size

 

 

 

ceiling height

 

 

 

 

ceiling height

 

W

L

 

 

8.5

10.0

13.0

16.0

 

 

8.5

10.0

13.0

16.0

20

20

 

 

 

56

60

66

73

 

 

53

57

63

70

20

30

 

 

 

50

53

57

63

 

 

46

50

54

60

20

40

 

 

 

47

49

53

57

 

 

42

45

49

53

20

60

 

 

 

43

46

49

52

 

 

38

41

44

48

30

20

 

 

 

58

61

66

72

 

 

56

60

63

69

30

30

 

 

 

51

54

57

62

 

 

48

51

54

59

30

40

 

 

 

47

49

52

55

 

 

43

46

49

52

30

60

 

 

 

43

46

47

50

 

 

38

41

43

47

30

60

 

lengthwise

 

42

44

45

48

 

crosswise

36

39

40

44

40

40

 

 

48

50

52

55

 

44

47

50

53

40

20

 

 

 

59

63

67

71

 

 

58

62

65

70

40

30

 

 

 

52

55

58

62

 

 

50

53

56

60

40

60

 

luminaries

 

44

46

48

50

 

luminaries

39

42

44

47

40

80

 

 

42

44

44

47

 

37

39

40

43

40

100

 

 

 

42

43

43

45

 

 

36

38

38

41

60

30

 

 

 

53

56

59

63

 

 

51

55

57

61

60

40

 

 

 

48

51

53

56

 

 

46

49

51

54

60

60

 

 

 

44

47

48

50

 

 

40

43

44

48

 

 

 

60

80

 

 

 

42

44

44

47

 

 

38

40

40

43

60

100

 

 

 

42

43

42

45

 

 

37

38

38

41

100

40

 

 

 

51

53

55

58

 

 

49

52

54

57

100

60

 

 

 

47

49

49

52

 

 

44

46

47

50

100

80

 

 

 

44

46

46

48

 

 

41

42

43

46

100

100

 

 

 

43

44

43

46

 

 

39

40

40

41

ORDERING INFORMATION

Explanation of Catalog Number. Example: SPS2GFSVA26U120SORF

SP

 

S

 

2

 

 

 

 

 

VA

2

6U

SPECPLUS:

Recessed

fluorescent

troffer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIXTURE

 

LENS FRAME:

 

LAMP

 

VOLTAGE:

 

 

 

OPTIONS:

 

 

WIDTH

 

FS= Flat steel frame

 

QUANTITY

 

120 or 277

 

 

Add appropriate suf-

 

 

 

 

 

 

RA=Regressed

 

 

 

 

 

 

 

 

fix to catalog no., ie:

 

 

 

 

 

 

aluminum frame

 

 

 

 

 

 

 

 

 

(GLR)

 

 

 

 

 

 

FA=Flat aluminum frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BALLAST TYPE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-2 Lamp Mag. T12

LE

 

 

STATIC

 

 

 

 

 

CEILING TYPE:

 

 

LENS/SHIELDING TYPE:

LAMP/

<10THD

 

 

 

 

 

 

 

 

 

 

<20THD

 

 

 

 

G= Grid (lay-in T bar)

 

 

VA (virgin acrylic)

FIXTURE LENGTH:

1-2 Lamp Elec. T8

SO*

HI*

 

 

 

 

 

F=Flanged (overlap) Z spline

 

 

standard (see options and

6"U Lamp

 

 

 

 

 

 

LOL T8 Dimming

PS

 

 

 

 

 

and plaster frame

 

 

consult factory)

T8 or T12

 

 

 

 

 

 

 

*Instant Start Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Nominal 24")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other dimming options. Consult factory.

OPTIONS/ACCESSORIES

SPECIAL LENSES: Substitute VB for VA (standard) = .125" nominal pattern 12 with 7.8 oz. aver- age weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per square foot.

PLASTER FRAME: Catalog Number PF22 .

CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges are required

between fixtures. Order Catalog Number: S2FCTRIM (each joint).

RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.

FUSING: Internal fast-blow fusing.

SUFFIX: GLR.

Internal slow-blow fusing.

SUFFIX: GMF.

ELECTRICAL/WIRING OPTIONS: Consult factory.

DRYWALL KIT: Order Catalog Number: FK92X2.

Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To prevent glare the VCP shall be not less than 40 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2629 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.4%.

SPECIFICATIONS (continued)

MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling.

FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating.

LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). VB (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Companywww.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier SPS2GFSVA26U Page 2 of, Photometry, Ordering Information, Options/Accessories, Specifications, Job Information