SECTION 2/Folio G05-26 REV. A

 

VP PARABOLIC VPA2G29PR232

Page 2 of 2

2'x4' RECESSED FLUORESCENT, 4" DEEP, 18 CELL (2x9) PARABOLIC LOUVER

 

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)

PHOTOMETRY

 

LER = FP - 63.8

IW - 61.2 BF - 96.2

 

 

 

 

 

 

 

 

MODEL NO. VPA2G29PR232SO Comparative yearly lighting energy cost per 1000 lumens = $3.76

 

 

 

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

 

 

 

RF

 

 

20

 

 

 

 

 

20

 

 

 

 

 

20

 

 

 

 

RC

 

 

80

 

 

 

 

 

50

 

 

 

 

 

30

 

 

 

 

RW

 

70

50

 

 

30

 

50

30

 

10

 

 

50

30

10

 

 

 

1

 

78

76

 

 

74

 

72

70

 

69

 

 

69

68

67

 

 

ratio

2

 

73

69

 

 

65

 

65

63

 

60

 

 

63

61

59

 

 

3

 

68

62

 

 

58

 

59

56

 

53

 

 

58

55

52

 

 

cavity

4

 

63

56

 

 

51

 

54

50

 

47

 

 

52

49

46

 

 

5

 

59

51

 

 

46

 

49

45

 

41

 

 

48

44

41

 

 

room

6

 

54

46

 

 

41

 

45

40

 

37

 

 

44

40

36

 

 

7

 

51

42

 

 

37

 

41

36

 

33

 

 

40

36

33

 

 

 

8

 

47

39

 

 

33

 

37

33

 

29

 

 

36

32

29

 

 

 

9

 

44

35

 

 

30

 

34

30

 

26

 

 

34

29

26

 

 

 

10

 

41

33

 

 

27

 

32

27

 

24

 

 

31

27

24

 

 

visual comfort probability

(rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

 

 

W

 

 

L

 

 

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

 

20

 

 

20

 

 

 

92

95

95

87

 

 

 

94

94

92

 

85

 

20

 

 

30

 

 

 

92

95

95

87

 

 

 

94

94

93

 

88

 

20

 

 

40

 

 

 

93

95

95

88

 

 

 

95

94

93

 

88

 

 

20

 

 

60

 

 

 

93

95

95

88

 

 

 

95

94

93

 

88

 

30

 

 

20

 

 

 

92

95

95

89

 

 

 

94

94

93

 

87

 

30

 

 

30

 

 

 

93

95

96

89

 

 

 

95

94

93

 

89

 

30

 

 

40

 

 

 

93

95

96

89

 

 

 

95

94

93

 

89

 

30

 

 

60

 

 

 

93

95

96

89

 

 

 

95

94

93

 

90

 

 

30

 

 

80

 

lengthwise

 

93

95

96

90

 

 

crosswise

95

94

93

 

90

 

40

 

 

40

 

 

93

95

96

91

 

 

95

94

93

 

90

 

40

 

 

20

 

 

 

92

95

95

91

 

 

 

94

94

93

 

88

 

40

 

 

30

 

luminaries

 

93

95

96

91

 

 

luminaries

95

94

93

 

89

 

40

 

 

60

 

 

93

95

96

91

 

 

95

94

93

 

90

 

40

 

 

80

 

 

 

93

95

96

91

 

 

 

95

94

93

 

90

 

 

40

 

 

100

 

 

 

93

96

96

91

 

 

 

95

94

93

 

90

 

60

 

 

30

 

 

 

93

95

96

91

 

 

 

95

94

93

 

89

 

60

 

 

40

 

 

 

93

95

96

91

 

 

 

95

94

93

 

90

 

60

 

 

60

 

 

 

93

96

96

91

 

 

 

95

94

93

 

90

 

 

 

 

 

 

 

 

 

 

 

60

 

 

80

 

 

 

93

96

96

91

 

 

 

95

94

93

 

90

 

 

60

 

 

100

 

 

 

93

96

95

91

 

 

 

95

94

93

 

90

 

100

 

 

40

 

 

 

93

95

96

91

 

 

 

95

94

93

 

90

 

100

 

 

60

 

 

 

93

96

95

91

 

 

 

95

94

93

 

90

 

100

 

 

80

 

 

 

93

96

95

91

 

 

 

95

94

94

 

90

 

 

100

 

 

100

 

 

 

93

96

95

91

 

 

 

95

94

94

 

90

ORDERING INFORMATION

Explanation of Catalog Number. Example: VPA2G29PR232120SOGLR

VP

 

A

 

2

 

 

 

29

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R 2

 

BODY STYLE:

 

CEILING TYPE:

 

LOUVER

 

A=Air Handling

 

G=Grid

 

FINISH*:

 

S=Static

 

(lay-in T bar)

 

P=Low

VP:

 

FIXTURE

F=Flanged

NUMBER OF

Iridescence

 

(overlap)

Specular

4" Deep

WIDTH

CELLS:

Z spline and

 

Pre-anodized

 

(2 rows of

 

 

plaster frame

 

Aluminum

 

9 cells)

 

 

T=Slot grid or

 

Louver

 

 

 

For Intense

two-directional

concealed T

VDT Use

(see options)

 

 

LAMP

 

 

QUANTITY

 

PREMIUM

 

LAMP TYPE/

SPECULAR

 

FIXTURE

 

REFLECTOR

 

LENGTH:

 

 

32=T8

 

 

34=T12

 

 

(Nominal 48")

VOLTAGE:

OPTIONS:

120 or 277

Add appropriate

 

 

suffix to catalog

 

 

no, ie: (GLR)

 

BALLAST TYPE:

 

1-2

Lamp Mag. T12

LE

<10THD

 

 

<20THD

1-2

Lamp Elec. T8

SO*

HI*

LOL T8 Dimming

PS

*Instant Start Standard

Other dimming options consult factory.

OPTIONS & ACCESSORIES

PLASTER FRAME: Catalog Number: PF24.

CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are

required between fixtures, Order Catalog Number: S2FCTRIM (each joint).

SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ24 S2 SPLAY TRIM.

RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: RF.

ELECTRICAL/WIRING OPTIONS: Consult factory.

AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed).

DRYWALL KIT: Order Catalog Number: FK92X4. Request Folio OA30-10.

CHICAGO PLENUM: SUFFIX: CP.

SPECIFICATIONS

PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .76 with a spacing to mounting ratio of 1.8 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba- bility) shall not be less than 93 either crosswise or lengthwise and the maximum average brightness at 55°, 65°, 75° and 85° shall not exceed 834, 0, 0 and 0 can- delas per square meter respectively in the 0°, 45°, and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 1437.

SPECIFICATIONS (continued)

AIR HANDLING: (VPA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com- partment through fixture body ends.

MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal).

FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence specular anodized vertical grain aluminum reflector sheet is standard.

ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS: I.B.E.W./UL and C-UL.

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902

Page 2
Image 2
Lightolier VPA2G29PR232 dimensions Photometry, Ordering Information, Options & Accessories, Specifications

VPA2G29PR232 specifications

The Lightolier VPA2G29PR232 is an innovative architectural troffer fixture designed to provide exceptional lighting quality while addressing energy efficiency and versatility. This fixture is particularly beneficial for commercial and residential interior spaces where effective illumination is essential.

One of the standout features of the VPA2G29PR232 is its integrated LED technology. The use of LEDs not only enhances the fixture's energy efficiency but also extends its lifespan compared to traditional fluorescent fixtures. With an impressive lumen output, the VPA2G29PR232 delivers bright, consistent lighting that can improve visibility and productivity in workspaces, retail environments, and educational facilities.

The design of the VPA2G29PR232 is sleek and modern, making it a suitable choice for a variety of settings. Its low-profile appearance allows it to seamlessly integrate into ceilings, providing a clean aesthetic while minimizing glare. This thoughtful design ensures that the fixture complements the overall interior design of a space without drawing unnecessary attention.

Another key characteristic of the VPA2G29PR232 is its versatility in terms of installation. It can be easily mounted in different grid systems, making it adaptable to various ceiling types. This flexibility allows for straightforward renovations or new constructions, as the fixture can fit into standard ceiling grids without specialized modifications.

The VPA2G29PR232 also incorporates advanced thermal management technologies, which help maintain optimal operating temperatures for the LEDs. This capability not only enhances performance but also contributes to energy savings by ensuring that the fixture runs efficiently over time.

Additionally, this troffer fixture is designed with user-centric features, including compatibility with dimming controls. This adaptability offers users the ability to customize their lighting environment according to specific needs, promoting comfort and enhancing the overall atmosphere of the space.

In summary, the Lightolier VPA2G29PR232 is a cutting-edge troffer fixture that excels in its energy efficiency, design, and adaptability. Its combination of high-performance LED technology, sleek aesthetic, and user-friendly features makes it an optimal choice for anyone looking to enhance their lighting solution while also maximizing energy savings. With the VPA2G29PR232, users can expect quality, versatility, and reliability in one powerful package.