Photometry
Model No. WMRL244120SB LER = FP - 51.6 IW - 86.7 BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $4.65
coefficients of utilization — zonal cavity method
| RF |
| 20 |
|
| 20 |
|
| 20 |
|
| RC |
| 80 |
|
| 50 |
|
| 30 |
|
| RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
ratio | 1 | 81 | 77 | 74 | 72 | 70 | 68 | 70 | 67 | 66 |
3 | 67 | 59 | 52 | 55 | 50 | 46 | 53 | 49 | 45 | |
| 2 | 73 | 67 | 62 | 63 | 59 | 55 | 60 | 57 | 54 |
cavity | 4 | 61 | 52 | 45 | 49 | 43 | 39 | 47 | 42 | 38 |
5 | 56 | 46 | 39 | 44 | 38 | 33 | 42 | 37 | 33 | |
room | 6 | 51 | 41 | 34 | 39 | 33 | 29 | 38 | 33 | 29 |
8 | 44 | 34 | 27 | 32 | 27 | 23 | 31 | 26 | 23 | |
| 7 | 48 | 37 | 31 | 35 | 30 | 26 | 34 | 29 | 25 |
| 9 | 41 | 31 | 25 | 30 | 24 | 20 | 29 | 24 | 20 |
| 10 | 39 | 29 | 22 | 27 | 22 | 18 | 27 | 22 | 18 |
FOOTCANDLES ON WALL Fixtures 3 feet from wall to outside trim on lamp side of fixture
Ceiling 8' 7' 6' 5' 4' 3' 2' 1'
Floor
|
|
| INDIVIDUAL WALMASTER |
|
|
|
|
|
|
| MULTIPLE UNITS |
|
|
|
|
|
| |||||||||
|
| 0' | 1' | 2' | 3' | 4' | 5' | 6' | 7' |
|
|
|
| 0 |
|
| 6' |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 116 | 88 | 51 | 30 | 19 | 13 | 10 | 08 |
| 135 | 109 | 077 | 67 | 077 | 110 | 137 |
|
| |||||||
|
| 119 | 102 | 71 | 45 | 28 | 18 | 14 | 11 |
| 142 | 130 | 108 | 88 | 109 | 133 | 147 |
|
| |||||||
|
| 092 | 083 | 64 | 45 | 31 | 22 | 16 | 12 |
| 117 | 114 | 104 | 99 | 105 | 117 | 123 |
|
| |||||||
|
| 069 | 064 | 53 | 40 | 30 | 22 | 16 | 13 |
| 095 | 095 | 092 | 90 | 094 | 099 | 192 |
|
| |||||||
|
| 052 | 050 | 43 | 35 | 27 | 21 | 17 | 13 |
| 079 | 080 | 079 | 79 | 081 | 084 | 086 |
|
| |||||||
|
| 040 | 039 | 35 | 30 | 24 | 19 | 15 | 13 |
| 066 | 067 | 067 | 69 | 070 | 071 | 072 |
|
| |||||||
|
| 032 | 031 | 29 | 25 | 21 | 17 | 15 | 12 |
| 056 | 057 | 058 | 59 | 060 | 061 | 061 |
|
| |||||||
|
| 026 | 025 | 23 | 21 | 18 | 15 | 13 | 12 |
| 047 | 049 | 050 | 51 | 051 | 052 | 052 |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MULTIPLE UNITS |
|
|
| CONTINUOUS ROW |
|
|
| ||
0Ceiling | 8' | 0' | 1' | 2' | 3' | 4' | 5' | 6' | 7' | 8' |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
8' | 124 | 097 | 61 | 43 | 37 | 43 | 61 | 97 | 124 | 151 | 134 | 119 | 139 | 162 | 140 | 122 | 140 | 162 |
7' | 128 | 113 | 85 | 65 | 58 | 65 | 85 | 113 | 128 | 166 | 167 | 164 | 176 | 186 | 178 | 170 | 178 | 186 |
6' | 102 | 095 | 80 | 67 | 62 | 67 | 80 | 096 | 102 | 142 | 149 | 152 | 159 | 164 | 162 | 159 | 162 | 164 |
5' | 080 | 077 | 69 | 62 | 59 | 62 | 70 | 77 | 080 | 119 | 126 | 131 | 136 | 139 | 139 | 139 | 139 | 139 |
4' | 064 | 063 | 60 | 56 | 54 | 56 | 60 | 63 | 064 | 100 | 106 | 112 | 115 | 117 | 118 | 119 | 118 | 117 |
3' | 052 | 052 | 51 | 49 | 47 | 49 | 51 | 52 | 052 | 085 | 090 | 094 | 097 | 099 | 100 | 101 | 100 | 099 |
2' | 043 | 044 | 43 | 42 | 42 | 42 | 43 | 44 | 043 | 073 | 077 | 080 | 083 | 085 | 086 | 086 | 086 | 085 |
1' | 035 | 036 | 36 | 36 | 36 | 36 | 36 | 36 | 036 | 063 | 066 | 068 | 070 | 072 | 072 | 073 | 072 | 072 |
Floor
Ordering Information
Explanation of Catalog Number. Example: WMRL244120SBGLR
WM
R
L
2
4
Walmaster: | Recessed | Reflector: | Lamps | Length: |
Low iridescent |
| L = Low iridescent |
| 4=48" |
|
|
| ||
|
|
| ||
wallwash |
| aluminum |
|
|
Options/Accessories
Fusing: Internal
Radio Interference Filter: To order one RIF per fixture, Suffix: R.
To order one RIF per ballast, Suffix: B.Electrical/Wiring Options: Consult factory.Fluorescent Emergency Lighting System:
battery pack with charger and inverter. Suffix: EM.
Drywall Frame: Catalog Number: WL4DF/UNV.Specifications
|
|
|
|
| Options: |
Watts: | Voltage: |
|
|
| |
1=18 Watts | 120 or 277 |
|
|
| Add appropriate |
2=24 Watts |
|
|
|
| suffix to catalog |
| |||||
4=40 Watts |
|
|
|
| no, ie: (GLR) |
5=50 Watts |
| Ballast Type: | |||
6=55 Watts |
|
|
| <20THD <10THD |
2 Lamp Magnetic (TT5) | BX* | – |
(40 Watt) |
|
|
2 Lamp Electronic (TT5) | BA* | – |
(18 Watt) |
|
|
2 Lamp Electronic (TT5) | BB* | – |
(24 Watt) |
| IB* |
2 Lamp Electronic (TT5) | SB* | |
(40 Watt) |
|
|
2 Lamp Electronic (TT5) | BE* | BP |
(50 Watt) |
|
|
2 Lamp Electronic (TT5) | BF | |
(55 Watt) |
|
|
LOL (TT5) Dimming | PB** | – |
(40 Watt) |
|
|
*Instant Start Standard |
|
|
Materials: Chassis parts are
Finish: Chassis
Electrical: Rapid start HPF, thermally protected class “P” ballast (Biax type). If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.optional drywall frame WL4DF/UNV.
Job Information | Type: |
|
|
Lightolier a Genlyte Company | www.lightolier.com |
Technical Information: (978) | |
631 Airport Road, Fall River, MA 02720 • (508) | |
We reserve the right to change details of design, materials and finish. | |
© 2005 a Genlyte company | Section5/Folio |