SEQUENCE OF OPERATIONS
IMPINGER ELECTRIC LOW PROFILE ADVANTAGE
(WITH PUSH BUTTON CONTROL)
| MODEL | 230/400 VAC | 50HZ |
| MODEL | 220/380 VAC | 50HZ |
| MODEL | 224/415 VAC | 50HZ |
|
| ||
POWER SUPPLY | Electrical power to be supplied to the oven by a five conductor service. | ||
| Brown conductor is hot. |
|
|
| Black conductor is hot. |
|
|
| Black conductor is hot. |
|
|
| Blue conductor is neutral. |
|
|
| Green conductor is ground. |
|
|
CONTROL BOX | When the temperature in either one of the control boxes reaches 120°F ±3° (49°C ± | ||
AUTO COOL DOWN | ° |
|
|
| 1.7 ), the cooling fan thermostats will switch power to the cooling fans. The thermostats | ||
| will interrupt power to the cooling fans when the temperature falls to 100°F ± 3° (37°C ± | ||
| 1.7°) |
|
|
MAIN FAN CIRCUIT | Line voltage is permanently supplied (through a power filter) to a normally open contact of | ||
| the oven power switch. Line voltage is permanently supplied to the two normally open | ||
| cooling fan thermostats. Closing the oven power switch supplies line voltage, through both | ||
| normally closed control box | ||
| close supplying line voltage to the two main fan motors. Closing the oven power switch also | ||
| supplies line voltage to the control box cooling fans, the oven control, the control | ||
| transformer, and the conveyor motor. |
| |
TEMPERATURE | Closing the oven power switch supplies line voltage, through the 10 amp. fuse, through the | ||
CONTROL | oven power relay, to the primary of the control transformer. 24VAC is supplied to the oven | ||
| control. The oven control is set to desired temperature. The thermocouple will provide | ||
| varying millivolts to the oven control. The oven control supplies line voltage to the contactor | ||
| at intermittent intervals to maintain desired temperature. The display on the oven control | ||
| will indicate when the contactor is energized. |
| |
| NOTE: The display also indicates oven temperature. | ||
CONVEYOR DRIVE | Closing the oven power switch supplies line voltage, through the 10 Amp fuse, through the | ||
| oven power relay to the conveyor motor and to the primary of the control transformer. | ||
| Secondary voltage, 24VAC, is supplied to the oven control. Setting the oven control to the | ||
| desired time, outputs voltage, through a reversing switch, to the conveyor motor | ||
| NOTE: The conveyor system uses a magnet and hall effect sensor to prove operation of | ||
| the conveyor motor. If the conveyor motor is not running, “BELT JAM” is indicated on the | ||
| display. |
|
|
AUTOMATIC COOL | When the oven is started, the time delay relay timing circuit is enabled, permitting the oven | ||
DOWN | fans to operate for approximately 20 minutes after the oven is shut off, to cool the oven. | ||
| The time delay relay will keep the coil of the motor relay closed, maintaining operation of | ||
| main fan and cooling motors. |
|
|
2 | Low Profile – 1600 Series Adv Dig Electric S.M. – Int’l |