TROUBLESHOOTING GUIDE
|
| MODEL | 230/400 VAC | 50 HZ | 3 PHASE | ||
|
| MODEL | 220/380 VAC | 50 HZ | 3 PHASE | ||
|
| MODEL | 240/415 VAC | 50 HZ | 3 PHASE | ||
| NOTE: When checking components on left side of unit, be sure to check for proper connections in power | ||||||
| connector, (marked P. C. on schematic diagram) located inside motor cover. | ||||||
|
|
|
|
|
|
| |
| SYMPTOM | POSSIBLE CAUSE |
| EVALUATION |
|
| |
| Oven fan will not | Incoming power supply |
| Check breakers/ reset if required call Power company |
| ||
| run |
|
| if needed. |
|
| |
|
| Fuse, 10 A., main fan |
| Check, replace if necessary. |
| ||
|
| Fuse holder |
| Check, replace if necessary. |
| ||
|
| Filter, Power |
| Check for supply voltage to filter. If there is no voltage, |
| ||
|
|
|
| trace wiring back to fuse holder. If there is power in to |
| ||
|
|
|
| the filter, but no power out, replace the filter. |
| ||
|
| Oven fan switch |
| Check continuity between switch terminals. |
| ||
|
| 20 minute time delay relay |
| Check for supply voltage to terminal #1 and #3, if |
| ||
|
|
|
| there is no voltage, trace wiring back to the power |
| ||
|
|
|
| filter. If voltage is present, check for supply voltage at |
| ||
|
|
|
| terminals #3 to #6, if no voltage is present, trace |
| ||
|
|
|
| wiring back to on/off switch. If there is voltage at #3 |
| ||
|
|
|
| and #6, check for voltage at terminals #1 and #2, of |
| ||
|
|
|
| there is no voltage at Terminals #1 and #2, replace |
| ||
|
|
|
| the 20 minute time delay relay. |
| ||
|
| Relay, main fan motors |
| Check for power to coil of motor relay. If no voltage is |
| ||
|
|
|
| present, trace wiring back to 20 minute time delay |
| ||
|
|
|
| relay. Check for supply voltage to the contact of the |
| ||
|
|
|
| relay. If no voltage is present, trace wiring back to |
| ||
|
|
|
| power filter. If voltage is present, at the relay coil, |
| ||
|
|
|
| check to insure the contacts are closing. Replace |
| ||
|
|
|
| relay as needed. |
|
| |
|
|
| Terminals are normally closed, if open, reset |
| |||
|
| box |
| thermostat and test oven for proper operation. If it will |
| ||
|
|
|
| not reset, replace thermostat. |
| ||
|
| Capacitor(s) |
| Check for opens, shorts, or grounds. |
| ||
|
| Motor(s), main fan |
| Check for opens, shorts, or grounds. |
| ||
| No main fan cool | 20 minute time delay relay |
| Check for supply voltage at terminals #1 and #2 while |
| ||
| down |
|
| is “ON”. Turn “OFF” the main fan switch, supply |
| ||
|
|
|
| voltage should continue to be present for 20 minutes. |
| ||
|
|
|
| If voltage is not present for 20 minutes, replace 20 |
| ||
|
|
|
| minute time delay relay. |
| ||
| No control box | Fan switch |
| (SEE OVEN FAN WILL NOT RUN.) |
| ||
| cooling |
| Terminals are normally closed, if open, reset |
| |||
|
|
|
| thermostat and test oven for proper operation. If it will |
| ||
|
|
|
| not reset, replace thermostat. |
| ||
|
| Relay, main fan motors |
| Check for power to coil of oven fan relay. If no voltage |
| ||
|
|
|
| is present, trace wiring back to |
| ||
|
|
|
| Check for supply voltage to the contact of the relay. If |
| ||
|
|
|
| no voltage is present, trace wiring back to fuse holder. |
| ||
|
|
|
| If voltage is present, at the relay coil, check to insure |
| ||
|
|
|
| the contacts are closing. Replace relay as needed. |
| ||
|
| Cooling fan(s) |
| Supply voltage should now be at these motors. If |
| ||
|
|
|
| voltage is present, check motor for open, shorts, or |
| ||
|
|
|
| grounds. WITH POWER OFF: check for locked rotor. |
| ||
| No automatic | Incoming power supply |
| Check circuit breakers, reset if needed. Call power |
| ||
| control box cooling |
|
| company if needed. |
| ||